Biomechanical comparison of unilateral semi-rigid and dynamic stabilization on ovine vertebrae

Using the unilateral pedicle screw fixation was thought to decrease the stiffness of the fixed segments. Various prospective, randomized studies were performed to determine whether unilateral pedicle screw fixation provides the necessities of bilateral fixation in one- or two-segment lumbar spinal f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine Journal of engineering in medicine, 2015-11, Vol.229 (11), p.778-785
Hauptverfasser: Karakoyun, Dursun O, Özkaya, Mustafa, Okutan, Volkan C, Dalgıç, Ali, Belen, Deniz, Demir, Teyfik
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Using the unilateral pedicle screw fixation was thought to decrease the stiffness of the fixed segments. Various prospective, randomized studies were performed to determine whether unilateral pedicle screw fixation provides the necessities of bilateral fixation in one- or two-segment lumbar spinal fusion. In this study, four different unilateral pedicle screw fixation systems were evaluated to determine which one best approximated an intact spine with respect to biomechanics and kinematics. The four groups included an intact group, a unilateral facetectomy group with no fixation, a unilateral semi-rigid pedicle screw fixation group with a poly-ether-ether-ketone rod, and a unilateral dynamic pedicle screw fixation group. The bone mineral densities of all specimens were measured and specimens were matched with groups randomly. Flexion, lateral bending, and axial rotation tests were performed to compare the groups. For the flexion, lateral bending, and axial rotation tests, the best biomechanical outcomes were in the control group. The unilateral facetectomy group had the poorest performance and was not stable enough, compared with the control group. The dynamic and semi-rigid groups showed performance closer to that of the control group. The biomechanical responses of these two groups were also in good agreement, showing no significant statistical differences. Based on these test results, it is concluded that the unilateral dynamic and semi-rigid pedicle screw fixations can be used to provide stability to the vertebrae.
ISSN:0954-4119
2041-3033
DOI:10.1177/0954411915612493