Clinically Significant Pocket Hematoma Increases Long-Term Risk of Device Infection: BRUISE CONTROL INFECTION Study
The BRUISE CONTROL trial (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial) demonstrated that a strategy of continued warfarin during cardiac implantable electronic device surgery was safe and reduced the incidence of clinically significant pocket hematoma (CSH). CSH was de...
Gespeichert in:
Veröffentlicht in: | Journal of the American College of Cardiology 2016-03, Vol.67 (11), p.1300-1308 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The BRUISE CONTROL trial (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial) demonstrated that a strategy of continued warfarin during cardiac implantable electronic device surgery was safe and reduced the incidence of clinically significant pocket hematoma (CSH). CSH was defined as a post-procedure hematoma requiring further surgery and/or resulting in prolongation of hospitalization of at least 24 h, and/or requiring interruption of anticoagulation. Previous studies have inconsistently associated hematoma with the subsequent development of device infection; reasons include the retrospective nature of many studies, lack of endpoint adjudication, and differing subjective definitions of hematoma.
The BRUISE CONTROL INFECTION (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial Extended Follow-Up for Infection) prospectively examined the association between CSH and subsequent device infection.
The study included 659 patients with a primary outcome of device-related infection requiring hospitalization, defined as 1 or more of the following: pocket infection; endocarditis; and bloodstream infection. Outcomes were verified by a blinded adjudication committee. Multivariable analysis was performed to identify predictors of infection.
The overall 1-year device-related infection rate was 2.4% (16 of 659). Infection occurred in 11% of patients (7 of 66) with previous CSH and in 1.5% (9 of 593) without CSH. CSH was the only independent predictor and was associated with a >7-fold increased risk of infection (hazard ratio: 7.7; 95% confidence interval: 2.9 to 20.5; p < 0.0001). Empiric antibiotics upon development of hematoma did not reduce long-term infection risk.
CSH is associated with a significantly increased risk of infection requiring hospitalization within 1 year following cardiac implantable electronic device surgery. Strategies aimed at reducing hematomas may decrease the long-term risk of infection. (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial [BRUISE CONTROL]; NCT00800137). |
---|---|
ISSN: | 0735-1097 1558-3597 |