Microarterial anastomoses: A parameterised computational study examining the effect of suture position on intravascular blood flow
This study investigates the extent to which individual aspects of suture placement influence local haemodynamics within microarterial anastomoses. An attempt to physically quantify flow characteristics of blood past microvascular sutures is made using computational fluid dynamics (CFD) software. Par...
Gespeichert in:
Veröffentlicht in: | Microvascular research 2016-05, Vol.105, p.141-148 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study investigates the extent to which individual aspects of suture placement influence local haemodynamics within microarterial anastomoses. An attempt to physically quantify flow characteristics of blood past microvascular sutures is made using computational fluid dynamics (CFD) software. Particular focus has been placed on increased shear strain rate (SSR), a known precipitant of intravascular platelet activation and thrombosis.
Measurements were taken from micrographs of sutured anastomoses in chicken femoral vessels, with each assessed for bite width, suture angle and suture spacing. Computational geometries were then created to represent the anastomosis. Each suture characteristic was parameterised to allow independent or simultaneous adjustment. Flow rates were obtained from anonymised Doppler ultrasound scans of analogous vessels during preoperative assessment for autologous breast reconstruction. Vessel simulations were performed in 2.5mm ducts with blood as the working fluid. Vessel walls were non-compliant and a continuous Newtonian flow was applied, in accordance with current literature.
Suture bite angle and spacing had significant effects on local haemodynamics, causing notably higher local SSRs, when simulated at extremes of surgical practice. A combined simulation, encompassing subtle changes of each suture parameter simultaneously i.e. representing optimum technique, created a more favourable SSR profile. As such, haemodynamic changes associated with optimum suture placement are unlikely to influence thrombus formation significantly. These findings support adherence to the basic principles of good microsurgical practice.
•Haemodynamics of microarterial anastomoses were modelled using computational fluid dynamics (CFD).•High shear strain rates (SSRs) are a known precipitant of platelet aggregation.•Greater suture angles from the standard perpendicular placement cause greater SSRs.•Sutures placed closely together cause greater SSRs.•Small variance in all parameters does not significantly influence flow properties. |
---|---|
ISSN: | 0026-2862 1095-9319 |
DOI: | 10.1016/j.mvr.2016.02.003 |