Experimental assessment of the kinetic parameters of the JSI TRIGA reactor

•Experimental data collected at the TRIGA reactor of the Jozef Stefan Institute.•Kinetic parameter measurements with cross spectral densities of fission chambers.•Experimental values agree with those provided by the TRIGA manufacturers Five core configurations corresponding to various control rod an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of nuclear energy 2015-09, Vol.83, p.236-245
Hauptverfasser: Filliatre, P., Jammes, C., Barbot, L., Fourmentel, D., Geslot, B., Lengar, I., Jazbec, A., Snoj, L., Z̆erovnik, G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Experimental data collected at the TRIGA reactor of the Jozef Stefan Institute.•Kinetic parameter measurements with cross spectral densities of fission chambers.•Experimental values agree with those provided by the TRIGA manufacturers Five core configurations corresponding to various control rod and chamber positions.•Demonstrated possibility of distinction between those configurations. An experimental campaign has been carried out at the TRIGA reactor of the Jozef Stefan Institute, in order to assess its mean neutron generation time Λ and effective delayed neutron fraction βeff. For that, the cross spectral densities (CPSD) of two fission chambers have been taken. The reactor has been operated in five core configurations corresponding to different control rod and chamber positions. A method of comparison between the cross spectral densities using the Welch statistical test, without assuming any kinetic model, has been performed; it shows that it is possible to distinguish between those configurations provided an high enough integration time (above 3000s) is used. Assuming a point-kinetic model, the parameters Λ and βeff have been robustly derived by a Cohn-α technique. The generation time is found to be rather constant from a configuration to another, but configurations with different fuel loading and control rod position yield an effective delayed neutron fraction that differ at 1σ level. The experimental values for both parameters agree with the values provided by the TRIGA manufacturers.
ISSN:0306-4549
1873-2100
DOI:10.1016/j.anucene.2015.03.054