Crack Detection in a Rotor Dynamic System by Vibration Monitoring—Part II: Extended Analysis and Experimental Results
An increase in the power-to-weight ratio demand on rotordynamic systems causes increased susceptibility to transverse fatigue cracking of the shaft. The ability to detect cracks at an early stage of progression is imperative for minimizing off-line repair time and cost. The vibration monitoring syst...
Gespeichert in:
Veröffentlicht in: | Journal of engineering for gas turbines and power 2012-11, Vol.134 (11), p.1-10 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An increase in the power-to-weight ratio demand on rotordynamic
systems causes increased susceptibility to transverse fatigue cracking of the
shaft. The ability to detect cracks at an early stage of progression is
imperative for minimizing off-line repair time and cost. The vibration
monitoring system initially proposed in Part I is employed herein, using the 2X
harmonic response component of the rotor tilt as a signature indicating a
transverse shaft crack. In addition, the analytic work presented in Part I is
expanded to include a new notch crack model to better approximate experimental
results. To effectively capture the 2X response, the crack model must include
the local nature of the crack, the depth of the crack, and the stiffness
asymmetry inducing the gravity-forced 2X harmonic response. The transfer matrix
technique is well suited to incorporate these crack attributes due to its
modular nature. Two transfer matrix models are proposed to predict the 2X
harmonic response. The first model applies local crack flexibility coefficients
determined using the strain energy release rate, while the second incorporates
the crack as a rectangular notch to emulate a manufactured crack used in the
experiments. Analytic results are compared to experimental measurement of the
rotor tilt gleaned from an overhung rotor test rig originally designed to
monitor seal face dynamics. The test rig is discussed, and experimental angular
response orbits and 2X harmonic amplitudes of the rotor tilt are provided for
shafts containing manufactured cracks of depths between 0% and 40%. Feasibility
of simultaneous multiple-fault detection of transverse shaft cracks and seal
face contact is discussed. |
---|---|
ISSN: | 0742-4795 1528-8919 |
DOI: | 10.1115/1.4007275 |