Vitamin-E blended and infused highly cross-linked polyethylene for total hip arthroplasty: A comparison of three-dimensional crystalline morphology and strain recovery behavior
Vitamin-E (α-tocopherol) is now recognized worldwide as one of the most promising antioxidant agents for highly cross-linked polyethylene (HXLPE) used in total joint replacements. In the contemporary manufacturing processes, two alternative methods are currently accepted to incorporate this antioxid...
Gespeichert in:
Veröffentlicht in: | Journal of the mechanical behavior of biomedical materials 2014-08, Vol.36, p.59-70 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Vitamin-E (α-tocopherol) is now recognized worldwide as one of the most promising antioxidant agents for highly cross-linked polyethylene (HXLPE) used in total joint replacements. In the contemporary manufacturing processes, two alternative methods are currently accepted to incorporate this antioxidant into polyethylene microstructure: (i) blending vitamin-E before consolidation and radiation crosslinking; (ii) infusing vitamin-E via a homogenizing heat treatment after radiation crosslinking. However, the effects of these technological differences on crystalline morphology and mechanical behavior of polyethylene remains to be fully elucidated. The aim of this paper is to quantitatively evaluate the microstructural differences of commercially available vitamin-E blended and infused HXLPE liner (referred to as Liner BL and IF, respectively). For this purpose, confocal/polarized Raman spectroscopy was used to systematically examine the three-phase percentages (amorphous (αa), crystalline (αc), and intermediate third phase (αt)), preferential molecular orientation (θp), and degree of crystalline anisotropy (〈P2(cosβ)〉). Additionally, we compared the time-dependent deformation of Liner BL and IF as obtained by uniaxial stress relaxation tests followed by strain recovery. Distinctive features of the near-surface αc, θp, and〈P2(cosβ)〉 were clearly observed within the first 35μm in the two studied liners. Despite the equivalent level of the bulk αc and 〈P2(cosβ)〉, higher restoring force against a uniaxial strain was observed in Liner IF, which reflects a higher crosslink density in its amorphous phase. On the other hands, a higher degree of surface orientational randomness was detected in Liner BL, which is structurally more beneficial for minimizing the in-vivo occurrence of strain-softening-assisted wear. |
---|---|
ISSN: | 1751-6161 1878-0180 |
DOI: | 10.1016/j.jmbbm.2014.04.004 |