Epidural Tube: A Useful Device in Sialendoscopy Operations

Salivary endoscopy, which was first described in 1991, is a safe technique with few complications. The sialendoscopy operation has been developed and successfully offered as a minimally invasive and gland-preserving approach for the treatment of chronic obstructive sialadenitis. For many surgeons, e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of oral and maxillofacial surgery 2016-03, Vol.74 (3), p.552-555
Hauptverfasser: Li, Jin, MD, Fang, Wei, MD, Chen, Ju-feng, MD, Long, Xing, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Salivary endoscopy, which was first described in 1991, is a safe technique with few complications. The sialendoscopy operation has been developed and successfully offered as a minimally invasive and gland-preserving approach for the treatment of chronic obstructive sialadenitis. For many surgeons, entering the duct lumen of the salivary gland is the most difficult and time-consuming step of the sialendoscopy operation. This report introduces a timesaving and straightforward method for entering the duct lumen using an epidural tube, which is a plastic tube with a blunt tip.
ISSN:0278-2391
1531-5053
DOI:10.1016/j.joms.2015.09.007