Computed Tomography Estimation of Cochlear Duct Length Can Predict Full Insertion in Cochlear Implantation

OBJECTIVE:To compare the rates of full insertion of electrodes and hearing outcomes obtained with 28-mm and 31-mm cochlear implant electrode arrays. To assess whether cochlear duct length (CDL) estimated by preoperative computed tomography (CT) predicts whether an electrode is fully inserted. STUDY...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Otology & neurotology 2016-03, Vol.37 (3), p.223-228
Hauptverfasser: Johnston, James D A, Scoffings, Daniel, Chung, Mark, Baguley, David, Donnelly, Neil P, Axon, Patrick R, Gray, Roger F, Tysome, James R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:OBJECTIVE:To compare the rates of full insertion of electrodes and hearing outcomes obtained with 28-mm and 31-mm cochlear implant electrode arrays. To assess whether cochlear duct length (CDL) estimated by preoperative computed tomography (CT) predicts whether an electrode is fully inserted. STUDY DESIGN:A cohort study compared electrodes inserted and hearing outcomes after implantation with 28-mm or 31-mm arrays. CDL estimated from preoperative CT was compared in patients in whom full insertion of the 28-mm array was achieved compared with patients in whom at least one basal electrode was outside the cochlea. SETTING:Tertiary referral cochlear implantation center. PATIENTS:One hundred forty-eight patients implanted with 28-mm cochlear implant arrays (175 devices) and 74 patients implanted with 31-mm arrays (88 devices). INTERVENTION:Cochlear implantation with 28-mm or 31-mm array. MAIN OUTCOME MEASURESActive electrodes at first programming, and at subsequent follow-ups. Bamford–Kowal–Bench sentence and auditory speech sound evaluation test results at 2 to 3 months in adult patients. CDL predicted by preoperative CT. RESULTS:There was no difference in full insertion between the 28-mm and 31-mm array cohorts (p = 0.22). Early hearing outcomes at 2 to 3 months showed no difference in mean auditory speech sound evaluation (p = 0.19) or Bamford–Kowal–Bench results (p = 0.853) between the 28-mm and 31-mm cohorts. CDL was shorter in the 22 patients with less than full insertion of the array with a mean length of 28.7 mm compared with 29.6 mm in the 42 patients in whom full insertion was achieved (p = 0.046). CONCLUSION:CT estimation of CDL predicts full insertion after cochlear implantation. Insertion depth does not affect early hearing outcome.
ISSN:1531-7129
1537-4505
DOI:10.1097/MAO.0000000000000955