High-throughput measurement of 25-hydroxyvitamin D by LC–MS/MS with separation of the C3-epimer interference for pediatric populations

Liquid chromatography–tandem mass spectrometry (LC–MS/MS) is widely used for the measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in blood. However, the presence of 25OHD3 C3-epimer (3-epi-25OHD3) may cause interference and overestimation of the 25OHD3 level. We develop...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinica chimica acta 2016-02, Vol.454, p.102-106
Hauptverfasser: Yang, Yifei, Rogers, Katherine, Wardle, Robert, El-Khoury, Joe M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Liquid chromatography–tandem mass spectrometry (LC–MS/MS) is widely used for the measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in blood. However, the presence of 25OHD3 C3-epimer (3-epi-25OHD3) may cause interference and overestimation of the 25OHD3 level. We developed a rapid and simple assay for measurement of 25OHD that separates this interference and to investigate its impact on 25OHD3 measurement in adult and pediatric populations. Sample preparation consisted of protein precipitation followed by solid-phase extraction with an LC run time of 4.8min. Method comparison with another LC–MS/MS method of a major reference laboratory that does not separate the C3-epimer interference was performed using adult (n=52) and pediatric (n=40) samples. This method is free from significant ion suppression, carryover and interference. The assay can separate 25OHD3 from the 3-epi-25OHD3, and can measure 25OHD2 and 25OHD3 from 4.2 to 310.7ng/ml and 5.2 to 311.1ng/ml, respectively. Method comparison with a LC–MS method that does not separate the interference revealed biases of −0.15 and 4.54 for 25OHD3 measurement in adult and pediatric samples, respectively. A fast and simple LC–MS/MS method for quantification of 25OHD3 and 25OHD2 without 3-epi-25OHD3 interference was developed. This assay is required for accurate quantitation of 25OHD3 in pediatric samples and suitable for routine use in a high volume clinical laboratory. •3-epi-25-hydroxyvitamin D3 is known to interfere with 25-hydroxyvitamin D3 by LC–MS.•The assay separates 3-epi-25-hydroxyvitamin D3 with total run time of just 4.8min.•The assay is fully validated for clinical use in high volume laboratories.•The assay is standardized to NIST SRM972a.
ISSN:0009-8981
1873-3492
DOI:10.1016/j.cca.2016.01.004