The Underground Sewer Drainage Design Analysis of Highway Subgrade Under Evaporation

According to the water balance principle, the expression of the phreatic table is established by considering evaporation and considering evaporation & drainage respectively. The law of phreatic table variation under the combined effects of considering evaporation & drainage is obtained. Based on New...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Shanghai jiao tong da xue xue bao 2013-06, Vol.18 (3), p.289-292
Hauptverfasser: Liu, Jie, Yao, Hai-lin, Lu, Zheng, You, Hui-jie, Duan, Jian-xin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:According to the water balance principle, the expression of the phreatic table is established by considering evaporation and considering evaporation & drainage respectively. The law of phreatic table variation under the combined effects of considering evaporation & drainage is obtained. Based on Newton-Raphson iterarive method, calculation and analysis programs are done to solve the first order implicit differential equation of the sewer drainage calculation considering phreatic evaporation. The calculation results show: after considering phreatic evaporation, in the need of reducing the same height of phreatic, the sewer spacing is appropriately larger than the case which didn't consider the affection of phreatic evaporation; the phreatic drop speed in both effects of evaporation and drainage is faster than the case of just considering the drainage effect. Phreatic evaporation has a great influence to the subgrade sewer distance, phreatic evaporation needs to be considered in the subgrade drainage design.
ISSN:1007-1172
1995-8188
DOI:10.1007/s12204-013-1396-z