First Model Power Cables Made of Russian 2G HTS Wires and their Test Results
Recently launched production of 2G wires by SuperOx Company permitted us to start tests of representative models of power cable made of their wires. In Russian Scientific R&D Cable Institute we have the test facility for extensive testing of heavily instrumented HTS cable models with full size c...
Gespeichert in:
Veröffentlicht in: | Journal of physics. Conference series 2014-01, Vol.507 (3), p.32063-4 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Recently launched production of 2G wires by SuperOx Company permitted us to start tests of representative models of power cable made of their wires. In Russian Scientific R&D Cable Institute we have the test facility for extensive testing of heavily instrumented HTS cable models with full size cross-section and length up to 5 m. Our standard test program includes critical current measurements, current distribution measurements among layers, AC loss measurements, etc. In this paper we present details of first power cable models made of 4 mm width 2G wires from SuperOx and their test results. Model cables have two counter-wound layers with 18 tapes in each layer. Critical currents of cables were from 3 kA to ~4.5 kA. We also measured AC losses and compared them with losses in model cables made of 2G wires of other producers. AC losses measured were compared with calculated ones and demonstrated the good coincidence between experiments and calculations. First model cables tests permitted us to conclude that SuperOx wires have good parameters for production of 2G HTS power cables with low AC losses. |
---|---|
ISSN: | 1742-6596 1742-6588 1742-6596 |
DOI: | 10.1088/1742-6596/507/3/032063 |