Shear wave elastography: An accurate technique to stage liver fibrosis in chronic liver diseases

Abstract Objectives The goals of this study were to assess the diagnostic accuracy of shear wave elastography (SWE) using the results of histopathological analysis as a standard of reference and compare the results of SWE and those of transient elastography (TE) to the degree of fibrosis as evaluate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diagnostic and interventional imaging 2016-01, Vol.97 (1), p.91-99
Hauptverfasser: Guibal, A, Renosi, G, Rode, A, Scoazec, J.Y, Guillaud, O, Chardon, L, Munteanu, M, Dumortier, J, Collin, F, Lefort, T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Objectives The goals of this study were to assess the diagnostic accuracy of shear wave elastography (SWE) using the results of histopathological analysis as a standard of reference and compare the results of SWE and those of transient elastography (TE) to the degree of fibrosis as evaluated by histomorphometry. Patients and methods Adult patients who were scheduled to undergo liver biopsy were prospectively enrolled in the study. The diagnostic performances of SWE were assessed using AUROC curve analysis according to fibrosis thresholds defined by ≥ F2 (significant fibrosis), ≥ F3 (advanced fibrosis) and F4 (cirrhosis). Additional analyses using the Obuchowski measures for pairwise comparisons of fibrosis stages were performed. In a subgroup of 55 patients, the relationships between stiffness as measured using SWE and TE and the percentage of fibrosis were compared using Spearman's rank coefficient. Results Among the initially enrolled 170 patients, 148/170 (87%) had successful SWE acquisition and formed the study population. SWE sensitivity and specificity were respectively 85.1% and 82.7% (≥ F2), 88.9% and 90.3% (≥ F3), 93.3% and 98.3% (F4). The AUROC curves of SWE along with their 95% confidence intervals (CI) were respectively 0.904 (95%CI: 0.845–0.946) for fibrosis ≥ F2; 0.958 (95%CI: 0.912–0.984) for fibrosis ≥ F3 and 0.988 (95%CI: 0.955–0.999) for fibrosis = F4. The global Obuchowski measure was 0.953 ± 0.007. In the subgroup study, a significant correlation was found between the percentage of fibrosis and stiffness as assessed by SWE ( r = 0.77; 95%CI: 0.63–0.86; P < 0.0001) and by TE ( r = 0.65; 95%CI: 0.47–0.78; P < 0.01). Conclusion SWE is accurate to assess liver fibrosis in patients with chronic liver disease.
ISSN:2211-5684
2211-5684
DOI:10.1016/j.diii.2015.11.001