β-Actin as a loading control: Less than 2 μg of total protein should be loaded
For the purpose of data normalization in Western blot analysis, journal editors and reviewers usually require authors to reprobe the Western blot membrane with a β‐actin‐specific antibody after detecting the target protein. In most cases, however, β‐actin is overloaded, which results in a failure to...
Gespeichert in:
Veröffentlicht in: | Electrophoresis 2015-09, Vol.36 (17), p.2046-2049 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | For the purpose of data normalization in Western blot analysis, journal editors and reviewers usually require authors to reprobe the Western blot membrane with a β‐actin‐specific antibody after detecting the target protein. In most cases, however, β‐actin is overloaded, which results in a failure to detect differences in protein loading. In this study, we attempted to optimize the amount of protein loaded for β‐actin detection to permit suitable Western blot analysis data normalization. Our data suggest that less than 2 μg of total protein should be loaded when β‐actin is used as a loading control. We also suggest avoiding reprobing the membrane with a β‐actin‐specific antibody. |
---|---|