Mesoscale Thermodynamic Influences on Convection Initiation near a Surface Dryline in a Convection-Permitting Ensemble
In this study, the authors examine initiation of severe convection along a daytime surface dryline in a 10-member ensemble of convection-permitting simulations. Results indicate that the minimum buoyancy B sub(min) of PBL air parcels must be small (B sub(min) > -0.5 degree C) for successful deep...
Gespeichert in:
Veröffentlicht in: | Monthly weather review 2015-09, Vol.143 (9), p.3726-3753 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this study, the authors examine initiation of severe convection along a daytime surface dryline in a 10-member ensemble of convection-permitting simulations. Results indicate that the minimum buoyancy B sub(min) of PBL air parcels must be small (B sub(min) > -0.5 degree C) for successful deep convection initiation (CI) to occur along the dryline. Comparing different ensemble members reveals that CAPE magnitudes (allowing for entrainment) and the width of the zone of negligible B sub(min) extending eastward from the dryline act together to influence CI. Since PBL updrafts that initiate along the dryline move rapidly northeast in the vertically sheared flow as they grow into the free troposphere, a wider zone of negligible B sub(min) helps ensure adequate time for incipient storms to mature, which, itself, is hastened by larger CAPE. Local B sub(min) budget calculations and trajectory analysis are used to quantify physical processes responsible for the reduction of negative buoyancy prior to CI. Here, the grid-resolved forcing and forcing from temperature and moisture tendencies in the PBL scheme (arising from surface fluxes) contribute about equally in ensemble composites. However, greater spatial variability in grid-resolved forcing focuses the location of the greatest net forcing along the dryline. The grid-resolved forcing is influenced by a thermally direct vertical circulation, where time-averaged ascent at the east edge of the dryline results in locally deeper moisture and cooler conditions near the PBL top. Horizontal temperature advection spreads the cooler air eastward above higher equivalent potential temperature air at source levels of convecting air parcels, resulting in a wider zone of negligible B sub(min) that facilitates sustained CI. |
---|---|
ISSN: | 0027-0644 1520-0493 |
DOI: | 10.1175/MWR-D-15-0133.1 |