The LED and fiber based calibration system for the photomultiplier array of SNO
A new external LED/fiber light injection calibration system was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. The goal of the calibration system is to allow an accurate and regular measurement of the photomultiplier array's performanc...
Gespeichert in:
Veröffentlicht in: | Journal of physics. Conference series 2015-01, Vol.587 (1), p.12031-5 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 5 |
---|---|
container_issue | 1 |
container_start_page | 12031 |
container_title | Journal of physics. Conference series |
container_volume | 587 |
creator | Seabra, L Alves, R Andringa, S Bradbury, S Carvalho, J Clark, K Coulter, I Descamps, F Falk, L Gurriana, L Kraus, C Lefeuvre, G Maio, A Maneira, J Mottram, M Peeters, S Rose, J Sinclair, J Skensved, P Waterfield, J White, R Wilson, J |
description | A new external LED/fiber light injection calibration system was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. The goal of the calibration system is to allow an accurate and regular measurement of the photomultiplier array's performance, while minimizing the risk of radioactivity ingress. The choice in SNO+ was to use a set of optical fiber cables to convey into the detector the light pulses produced by external LEDs. The quality control was carried out using a modified test bench that was used in QC of optical fibers for TileCal/ATLAS. The optical fibers were characterized for transmission, timing and angular dispersions. This article describes the setups used for the characterization and quality control of the system based on LEDs and optical fibers and their results. |
doi_str_mv | 10.1088/1742-6596/587/1/012031 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1753484250</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2576247237</sourcerecordid><originalsourceid>FETCH-LOGICAL-c364t-cd416d93ea1a9f34d14553cf9f49f8de991ac737b2965d00552e0398409addef3</originalsourceid><addsrcrecordid>eNpdkD1PwzAQhi0EEqXwF5AlFpYQf8b2iEr5kCI6UGbLiW01VRIHOxn670lV1IFb7qT3udPpAeAeoyeMpMyxYCQruCpyLkWOc4QJovgCLM7B5XmW8hrcpLRHiM4lFmCz3TlYrl-g6S30TeUirExyFtambapoxib0MB3S6DroQ4TjjA-7MIZuasdmaJt5wcRoDjB4-PW5uQVX3rTJ3f31Jfh-XW9X71m5eftYPZdZTQs2ZrVluLCKOoON8pRZzDintVeeKS-tUwqbWlBREVVwixDnxCGqJEPKWOs8XYLH090hhp_JpVF3Tapd25rehSlpLDhlkhGOZvThH7oPU-zn7zThoiBMECpmqjhRdQwpRef1EJvOxIPGSB8966NCfdSpZ88a65Nn-gvsrG8f</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2576247237</pqid></control><display><type>article</type><title>The LED and fiber based calibration system for the photomultiplier array of SNO</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Institute of Physics Open Access Journal Titles</source><source>IOPscience extra</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Seabra, L ; Alves, R ; Andringa, S ; Bradbury, S ; Carvalho, J ; Clark, K ; Coulter, I ; Descamps, F ; Falk, L ; Gurriana, L ; Kraus, C ; Lefeuvre, G ; Maio, A ; Maneira, J ; Mottram, M ; Peeters, S ; Rose, J ; Sinclair, J ; Skensved, P ; Waterfield, J ; White, R ; Wilson, J</creator><creatorcontrib>Seabra, L ; Alves, R ; Andringa, S ; Bradbury, S ; Carvalho, J ; Clark, K ; Coulter, I ; Descamps, F ; Falk, L ; Gurriana, L ; Kraus, C ; Lefeuvre, G ; Maio, A ; Maneira, J ; Mottram, M ; Peeters, S ; Rose, J ; Sinclair, J ; Skensved, P ; Waterfield, J ; White, R ; Wilson, J ; the SNO+ collaboration</creatorcontrib><description>A new external LED/fiber light injection calibration system was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. The goal of the calibration system is to allow an accurate and regular measurement of the photomultiplier array's performance, while minimizing the risk of radioactivity ingress. The choice in SNO+ was to use a set of optical fiber cables to convey into the detector the light pulses produced by external LEDs. The quality control was carried out using a modified test bench that was used in QC of optical fibers for TileCal/ATLAS. The optical fibers were characterized for transmission, timing and angular dispersions. This article describes the setups used for the characterization and quality control of the system based on LEDs and optical fibers and their results.</description><identifier>ISSN: 1742-6588</identifier><identifier>EISSN: 1742-6596</identifier><identifier>DOI: 10.1088/1742-6596/587/1/012031</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Arrays ; Cables ; Calibration ; Fibers ; Light emitting diodes ; Monitoring ; Multiplier phototubes ; Optical fibers ; Photomultiplier tubes ; Photomultipliers ; Physics ; Quality control ; Radioactivity</subject><ispartof>Journal of physics. Conference series, 2015-01, Vol.587 (1), p.12031-5</ispartof><rights>2015. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c364t-cd416d93ea1a9f34d14553cf9f49f8de991ac737b2965d00552e0398409addef3</citedby><cites>FETCH-LOGICAL-c364t-cd416d93ea1a9f34d14553cf9f49f8de991ac737b2965d00552e0398409addef3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27931,27932</link.rule.ids></links><search><creatorcontrib>Seabra, L</creatorcontrib><creatorcontrib>Alves, R</creatorcontrib><creatorcontrib>Andringa, S</creatorcontrib><creatorcontrib>Bradbury, S</creatorcontrib><creatorcontrib>Carvalho, J</creatorcontrib><creatorcontrib>Clark, K</creatorcontrib><creatorcontrib>Coulter, I</creatorcontrib><creatorcontrib>Descamps, F</creatorcontrib><creatorcontrib>Falk, L</creatorcontrib><creatorcontrib>Gurriana, L</creatorcontrib><creatorcontrib>Kraus, C</creatorcontrib><creatorcontrib>Lefeuvre, G</creatorcontrib><creatorcontrib>Maio, A</creatorcontrib><creatorcontrib>Maneira, J</creatorcontrib><creatorcontrib>Mottram, M</creatorcontrib><creatorcontrib>Peeters, S</creatorcontrib><creatorcontrib>Rose, J</creatorcontrib><creatorcontrib>Sinclair, J</creatorcontrib><creatorcontrib>Skensved, P</creatorcontrib><creatorcontrib>Waterfield, J</creatorcontrib><creatorcontrib>White, R</creatorcontrib><creatorcontrib>Wilson, J</creatorcontrib><creatorcontrib>the SNO+ collaboration</creatorcontrib><title>The LED and fiber based calibration system for the photomultiplier array of SNO</title><title>Journal of physics. Conference series</title><description>A new external LED/fiber light injection calibration system was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. The goal of the calibration system is to allow an accurate and regular measurement of the photomultiplier array's performance, while minimizing the risk of radioactivity ingress. The choice in SNO+ was to use a set of optical fiber cables to convey into the detector the light pulses produced by external LEDs. The quality control was carried out using a modified test bench that was used in QC of optical fibers for TileCal/ATLAS. The optical fibers were characterized for transmission, timing and angular dispersions. This article describes the setups used for the characterization and quality control of the system based on LEDs and optical fibers and their results.</description><subject>Arrays</subject><subject>Cables</subject><subject>Calibration</subject><subject>Fibers</subject><subject>Light emitting diodes</subject><subject>Monitoring</subject><subject>Multiplier phototubes</subject><subject>Optical fibers</subject><subject>Photomultiplier tubes</subject><subject>Photomultipliers</subject><subject>Physics</subject><subject>Quality control</subject><subject>Radioactivity</subject><issn>1742-6588</issn><issn>1742-6596</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpdkD1PwzAQhi0EEqXwF5AlFpYQf8b2iEr5kCI6UGbLiW01VRIHOxn670lV1IFb7qT3udPpAeAeoyeMpMyxYCQruCpyLkWOc4QJovgCLM7B5XmW8hrcpLRHiM4lFmCz3TlYrl-g6S30TeUirExyFtambapoxib0MB3S6DroQ4TjjA-7MIZuasdmaJt5wcRoDjB4-PW5uQVX3rTJ3f31Jfh-XW9X71m5eftYPZdZTQs2ZrVluLCKOoON8pRZzDintVeeKS-tUwqbWlBREVVwixDnxCGqJEPKWOs8XYLH090hhp_JpVF3Tapd25rehSlpLDhlkhGOZvThH7oPU-zn7zThoiBMECpmqjhRdQwpRef1EJvOxIPGSB8966NCfdSpZ88a65Nn-gvsrG8f</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Seabra, L</creator><creator>Alves, R</creator><creator>Andringa, S</creator><creator>Bradbury, S</creator><creator>Carvalho, J</creator><creator>Clark, K</creator><creator>Coulter, I</creator><creator>Descamps, F</creator><creator>Falk, L</creator><creator>Gurriana, L</creator><creator>Kraus, C</creator><creator>Lefeuvre, G</creator><creator>Maio, A</creator><creator>Maneira, J</creator><creator>Mottram, M</creator><creator>Peeters, S</creator><creator>Rose, J</creator><creator>Sinclair, J</creator><creator>Skensved, P</creator><creator>Waterfield, J</creator><creator>White, R</creator><creator>Wilson, J</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7SP</scope><scope>7U5</scope><scope>8BQ</scope><scope>JG9</scope></search><sort><creationdate>20150101</creationdate><title>The LED and fiber based calibration system for the photomultiplier array of SNO</title><author>Seabra, L ; Alves, R ; Andringa, S ; Bradbury, S ; Carvalho, J ; Clark, K ; Coulter, I ; Descamps, F ; Falk, L ; Gurriana, L ; Kraus, C ; Lefeuvre, G ; Maio, A ; Maneira, J ; Mottram, M ; Peeters, S ; Rose, J ; Sinclair, J ; Skensved, P ; Waterfield, J ; White, R ; Wilson, J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c364t-cd416d93ea1a9f34d14553cf9f49f8de991ac737b2965d00552e0398409addef3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Arrays</topic><topic>Cables</topic><topic>Calibration</topic><topic>Fibers</topic><topic>Light emitting diodes</topic><topic>Monitoring</topic><topic>Multiplier phototubes</topic><topic>Optical fibers</topic><topic>Photomultiplier tubes</topic><topic>Photomultipliers</topic><topic>Physics</topic><topic>Quality control</topic><topic>Radioactivity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Seabra, L</creatorcontrib><creatorcontrib>Alves, R</creatorcontrib><creatorcontrib>Andringa, S</creatorcontrib><creatorcontrib>Bradbury, S</creatorcontrib><creatorcontrib>Carvalho, J</creatorcontrib><creatorcontrib>Clark, K</creatorcontrib><creatorcontrib>Coulter, I</creatorcontrib><creatorcontrib>Descamps, F</creatorcontrib><creatorcontrib>Falk, L</creatorcontrib><creatorcontrib>Gurriana, L</creatorcontrib><creatorcontrib>Kraus, C</creatorcontrib><creatorcontrib>Lefeuvre, G</creatorcontrib><creatorcontrib>Maio, A</creatorcontrib><creatorcontrib>Maneira, J</creatorcontrib><creatorcontrib>Mottram, M</creatorcontrib><creatorcontrib>Peeters, S</creatorcontrib><creatorcontrib>Rose, J</creatorcontrib><creatorcontrib>Sinclair, J</creatorcontrib><creatorcontrib>Skensved, P</creatorcontrib><creatorcontrib>Waterfield, J</creatorcontrib><creatorcontrib>White, R</creatorcontrib><creatorcontrib>Wilson, J</creatorcontrib><creatorcontrib>the SNO+ collaboration</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Materials Research Database</collection><jtitle>Journal of physics. Conference series</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Seabra, L</au><au>Alves, R</au><au>Andringa, S</au><au>Bradbury, S</au><au>Carvalho, J</au><au>Clark, K</au><au>Coulter, I</au><au>Descamps, F</au><au>Falk, L</au><au>Gurriana, L</au><au>Kraus, C</au><au>Lefeuvre, G</au><au>Maio, A</au><au>Maneira, J</au><au>Mottram, M</au><au>Peeters, S</au><au>Rose, J</au><au>Sinclair, J</au><au>Skensved, P</au><au>Waterfield, J</au><au>White, R</au><au>Wilson, J</au><aucorp>the SNO+ collaboration</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The LED and fiber based calibration system for the photomultiplier array of SNO</atitle><jtitle>Journal of physics. Conference series</jtitle><date>2015-01-01</date><risdate>2015</risdate><volume>587</volume><issue>1</issue><spage>12031</spage><epage>5</epage><pages>12031-5</pages><issn>1742-6588</issn><eissn>1742-6596</eissn><abstract>A new external LED/fiber light injection calibration system was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. The goal of the calibration system is to allow an accurate and regular measurement of the photomultiplier array's performance, while minimizing the risk of radioactivity ingress. The choice in SNO+ was to use a set of optical fiber cables to convey into the detector the light pulses produced by external LEDs. The quality control was carried out using a modified test bench that was used in QC of optical fibers for TileCal/ATLAS. The optical fibers were characterized for transmission, timing and angular dispersions. This article describes the setups used for the characterization and quality control of the system based on LEDs and optical fibers and their results.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1742-6596/587/1/012031</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1742-6588 |
ispartof | Journal of physics. Conference series, 2015-01, Vol.587 (1), p.12031-5 |
issn | 1742-6588 1742-6596 |
language | eng |
recordid | cdi_proquest_miscellaneous_1753484250 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Institute of Physics Open Access Journal Titles; IOPscience extra; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry |
subjects | Arrays Cables Calibration Fibers Light emitting diodes Monitoring Multiplier phototubes Optical fibers Photomultiplier tubes Photomultipliers Physics Quality control Radioactivity |
title | The LED and fiber based calibration system for the photomultiplier array of SNO |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T05%3A36%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20LED%20and%20fiber%20based%20calibration%20system%20for%20the%20photomultiplier%20array%20of%20SNO&rft.jtitle=Journal%20of%20physics.%20Conference%20series&rft.au=Seabra,%20L&rft.aucorp=the%20SNO+%20collaboration&rft.date=2015-01-01&rft.volume=587&rft.issue=1&rft.spage=12031&rft.epage=5&rft.pages=12031-5&rft.issn=1742-6588&rft.eissn=1742-6596&rft_id=info:doi/10.1088/1742-6596/587/1/012031&rft_dat=%3Cproquest_cross%3E2576247237%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2576247237&rft_id=info:pmid/&rfr_iscdi=true |