Optimization of the Scintillator Size for Positron Lifetime Measurements
Optimization of the measurement condition for positron annihilation lifetime spectroscopy (PALS) is discussed from the viewpoint of non-destructive "on-site" material inspection. Numerical analysis based on a least-squares estimation and experiments with various sizes of BaF2 scintillators...
Gespeichert in:
Veröffentlicht in: | Journal of physics. Conference series 2013-06, Vol.443 (1), p.12099-4 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Optimization of the measurement condition for positron annihilation lifetime spectroscopy (PALS) is discussed from the viewpoint of non-destructive "on-site" material inspection. Numerical analysis based on a least-squares estimation and experiments with various sizes of BaF2 scintillators by conventional PALS suggested that the use of relatively large BaF2 scintillators enables on-site material inspection by PALS with reasonable accumulation time and time resolution. |
---|---|