Impact of motion induced artifacts on automatic registration of lung tumors in Tomotherapy

Highlights • We aimed to validate a tumor-based registration of lung tumors in Tomotherapy. • We explored the effect of motion-induced MV-CT artifacts on automatic registration. • Registration errors were acceptable (within 1.3 ± 1.2 mm). • Only breathing period of 5 s induced more significant regis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physica medica 2015-12, Vol.31 (8), p.963-968
Hauptverfasser: Goossens, Samuel, Descampe, Antonin, Orban de Xivry, Jonathan, Lee, John A, Delor, Antoine, Janssens, Guillaume, Geets, Xavier
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Highlights • We aimed to validate a tumor-based registration of lung tumors in Tomotherapy. • We explored the effect of motion-induced MV-CT artifacts on automatic registration. • Registration errors were acceptable (within 1.3 ± 1.2 mm). • Only breathing period of 5 s induced more significant registration errors. • This period should be avoided by applying audio guidance during MV-CT acquisition.
ISSN:1120-1797
1724-191X
DOI:10.1016/j.ejmp.2015.07.140