Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis

Abstract Background Context Pedicle screws are routinely used in contemporary spinal surgery. Screw misplacement may be asymptomatic but is also correlated with potential adverse events. Computer-assisted surgery (CAS) has been associated with improved screw placement accuracy rates. However, this t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The spine journal 2016-01, Vol.16 (1), p.23-31
Hauptverfasser: Dea, Nicolas, MD, MSc, Fisher, Charles G., MD, MHSc, Batke, Juliet, BSc, Strelzow, Jason, MD, Mendelsohn, Daniel, MD, Paquette, Scott J., MD, Kwon, Brian K., MD, PhD, Boyd, Michael D., MD, Dvorak, Marcel F.S., MD, Street, John T., MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Context Pedicle screws are routinely used in contemporary spinal surgery. Screw misplacement may be asymptomatic but is also correlated with potential adverse events. Computer-assisted surgery (CAS) has been associated with improved screw placement accuracy rates. However, this technology has substantial acquisition and maintenance costs. Despite its increasing usage, no rigorous full economic evaluation comparing this technology to current standard of care has been reported. Purpose Medical costs are exploding in an unsustainable way. Health economic theory requires that medical equipment costs be compared with expected benefits. To answer this question for computer-assisted spinal surgery, we present an economic evaluation looking specifically at symptomatic misplaced screws leading to reoperation secondary to neurologic deficits or biomechanical concerns. Study Design/Setting The study design was an observational case-control study from prospectively collected data of consecutive patients treated with the aid of CAS (treatment group) compared with a matched historical cohort of patients treated with conventional fluoroscopy (control group). Patient Sample The patient sample consisted of consecutive patients treated surgically at a quaternary academic center. Outcome Measures The primary effectiveness measure studied was the number of reoperations for misplaced screws within 1 year of the index surgery. Secondary outcome measures included were total adverse event rate and postoperative computed tomography usage for pedicle screw examination. Methods A patient-level data cost-effectiveness analysis from the hospital perspective was conducted to determine the value of a navigation system coupled with intraoperative 3-D imaging (O-arm Imaging and the StealthStation S7 Navigation Systems, Medtronic, Louisville, CO, USA) in adult spinal surgery. The capital costs for both alternatives were reported as equivalent annual costs based on the annuitization of capital expenditures method using a 3% discount rate and a 7-year amortization period. Annual maintenance costs were also added. Finally, reoperation costs using a micro-costing approach were calculated for both groups. An incremental cost-effectiveness ratio was calculated and reported as cost per reoperation avoided. Based on reoperation costs in Canada and in the United States, a minimal caseload was calculated for the more expensive alternative to be cost saving. Sensitivity analyses w
ISSN:1529-9430
1878-1632
DOI:10.1016/j.spinee.2015.09.062