Do 'Surgical Helmet Systems' or 'Body Exhaust Suits' Affect Contamination and Deep Infection Rates in Arthroplasty? A Systematic Review
Abstract This systematic review examined whether negative-pressure Charnley-type body exhaust suits (BES) or modern positive-pressure surgical helmet systems (SHS) reduce deep infection rates and/or contamination in arthroplasty. For deep infection, four studies (3990 patients) gave adjusted relativ...
Gespeichert in:
Veröffentlicht in: | The Journal of arthroplasty 2016, Vol.31 (1), p.225-233 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract This systematic review examined whether negative-pressure Charnley-type body exhaust suits (BES) or modern positive-pressure surgical helmet systems (SHS) reduce deep infection rates and/or contamination in arthroplasty. For deep infection, four studies (3990 patients) gave adjusted relative risk for deep infection of 0.11 (P = 0.09) against SHS. Five of 7 (71%) studies found less air contamination and 2 of 4 studies (50%) less wound contamination with BES. One of 4 (25%) found less air contamination with SHS and 0 of 1 (0%) less wound contamination. In contrast to BES, modern SHS designs were not shown to reduce contamination or deep infection during arthroplasty. |
---|---|
ISSN: | 0883-5403 1532-8406 |
DOI: | 10.1016/j.arth.2015.07.043 |