Fully automated 2D–3D registration and verification

•We propose algorithms that enable fully automated CT to X-ray registration.•Our techniques tackle the initialisation and result verification stages.•Registration capture range and speed suitable for clinical use.•A correct registration rate of 95% is produced for images within the capture range.•In...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical image analysis 2015-12, Vol.26 (1), p.108-119
Hauptverfasser: Varnavas, Andreas, Carrell, Tom, Penney, Graeme
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•We propose algorithms that enable fully automated CT to X-ray registration.•Our techniques tackle the initialisation and result verification stages.•Registration capture range and speed suitable for clinical use.•A correct registration rate of 95% is produced for images within the capture range.•Incorrect registrations are detected automatically. [Display omitted] Clinical application of 2D–3D registration technology often requires a significant amount of human interaction during initialisation and result verification. This is one of the main barriers to more widespread clinical use of this technology. We propose novel techniques for automated initial pose estimation of the 3D data and verification of the registration result, and show how these techniques can be combined to enable fully automated 2D–3D registration, particularly in the case of a vertebra based system. The initialisation method is based on preoperative computation of 2D templates over a wide range of 3D poses. These templates are used to apply the Generalised Hough Transform to the intraoperative 2D image and the sought 3D pose is selected with the combined use of the generated accumulator arrays and a Gradient Difference Similarity Measure. On the verification side, two algorithms are proposed: one using normalised features based on the similarity value and the other based on the pose agreement between multiple vertebra based registrations. The proposed methods are employed here for CT to fluoroscopy registration and are trained and tested with data from 31 clinical procedures with 417 low dose, i.e. low quality, high noise interventional fluoroscopy images. When similarity value based verification is used, the fully automated system achieves a 95.73% correct registration rate, whereas a no registration result is produced for the remaining 4.27% of cases (i.e. incorrect registration rate is 0%). The system also automatically detects input images outside its operating range.
ISSN:1361-8415
1361-8423
DOI:10.1016/j.media.2015.08.005