Headspace in-tube microextraction coupled with micellar electrokinetic chromatography of neutral aromatic compounds

Headspace (HS) extraction can be carried out easily and aptly via single drop microextraction coupled with capillary electrophoresis (CE). However, one drawback is the difficulty of keeping the single drop stably at the capillary tip. To solve this problem, we have recently demonstrated HS in-tube m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2016-02, Vol.148, p.729-733
Hauptverfasser: Cho, Sung Min, Park, Bum Su, Jung, Woo Sung, Lee, Sang Won, Jung, Yunhwan, Chung, Doo Soo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Headspace (HS) extraction can be carried out easily and aptly via single drop microextraction coupled with capillary electrophoresis (CE). However, one drawback is the difficulty of keeping the single drop stably at the capillary tip. To solve this problem, we have recently demonstrated HS in-tube microextraction (ITME) of acidic compounds such as chlrophenols in an acidic sample using a basic run buffer plug in the separation capillary for CE as an acceptor phase. In this report, an organic acceptor plug in a capillary was used to extract neutral organic volatile pollutants such as BTEX (benzene, toluene, ethylbenzene, and m-xylene). After extraction, the analytes enriched in the organic acceptor plug were analyzed with micellar electrokinetic chromatography (MEKC). The enrichment factors for BTEX in a standard solution were up to 350 under an optimal condition of 25°C for 20min. As an application, BTEX spiked into bottled water were analyzed with HS-ITME-MEKC, and the enrichment factors for BTEX were up to 320. The limits of detections were 1–4ppb, which are at least 200 times lower than the US Environmental Protection Agency guidelines for drinking water, except benzene. The entire procedure of HS-ITME-MEKC was carried out automatically using a commercial CE instrument. [Display omitted] •General applicability of in-tube microextraction was demonstrated.•Neutral compounds were enriched with headspace in-tube microextraction.•An organic acceptor plug was used for neutral organic compounds.•Headspace in-tube microextraction was in-line coupled with an MEKC mode of CE.•LODs for BITEX in drinking water were quite below the US EPA guidelines.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2015.11.035