Annual performance of an active solar distillation system
This paper presents the annual performance of an active solar still. Analytical expressions for water and glass cover temperatures and yield have been derived in terms of design and climatic parameters. Numerical computations have been carried out for Delhi climatic conditions (latitude = 28°35′ N,...
Gespeichert in:
Veröffentlicht in: | Desalination 2000-01, Vol.127 (1), p.79-88 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper presents the annual performance of an active solar still. Analytical expressions for water and glass cover temperatures and yield have been derived in terms of design and climatic parameters. Numerical computations have been carried out for Delhi climatic conditions (latitude = 28°35′ N, longitude = 77°12′E). It has been observed that for given parameters, the annual yield is optimum when the collector inclination is 20° and the still glass cover inclination is 15°. |
---|---|
ISSN: | 0011-9164 1873-4464 |
DOI: | 10.1016/S0011-9164(99)00194-0 |