Geothermal ground gas emissions and indoor air pollution in Rotorua, New Zealand

The emission of toxic gases from the soil is a hazard in geothermal regions that are also urbanised because buildings constructed on geothermal ground may be subject to the ingress of gases from the soil directly into the structure. The Rotorua geothermal field, New Zealand, is extensively urbanised...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Science of the total environment 2005-06, Vol.345 (1), p.69-80
Hauptverfasser: Durand, Michael, Scott, Bradley J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The emission of toxic gases from the soil is a hazard in geothermal regions that are also urbanised because buildings constructed on geothermal ground may be subject to the ingress of gases from the soil directly into the structure. The Rotorua geothermal field, New Zealand, is extensively urbanised but to date no studies have evaluated the extent of the ground gas hazard. The main gases emitted are hydrogen sulphide (H 2S) and carbon dioxide (CO 2), both of which are highly toxic and denser than air. This paper reports preliminary findings from a study of selected buildings constructed in the gas anomaly area. Properties were investigated for evidence of ingress by H 2S, CO 2, and 222Rn, with a view to determine the means and rates of gas entry and the nature of any consequent hazard. H 2S and CO 2 were investigated using infrared active gas analysers and passive detector tubes left in place for 10–48 h. 222Rn was measured over a period of 3 months by poly-allyl diglycol carbonate sensors. Eight of the nine buildings studied were found to suffer problems with soil gases entering the indoor air through the structure. The primary means of gas entry was directly from the ground through the floors, walls, and subsurface pipes. Indoor vents were located and found emitting up to ∼200 ppm H 2S and ∼15% CO 2, concentrations high enough to present an acute respiratory hazard to persons close to the vent (e.g., children playing at floor level). In some properties, gas problems occurred despite preventative measures having been made during construction or during later renovations. Typically, these measures include the under-laying of concrete floors with a gas-proof butanol seal, under-floor ventilation systems or the installation of positive-pressure air conditioning. Recently constructed buildings (
ISSN:0048-9697
1879-1026
DOI:10.1016/j.scitotenv.2004.10.023