Intensity calibration and atomic imaging of size-selected Au and Pd clusters in aberration-corrected HAADF-STEM
We report an experimental calibration of the exponent α, which relates intensity (I) and atomic number (Z) in HAADF-STEM imaging. The method employs size-selected Au923 and Pd923 clusters in an aberration-corrected 200 kV microscope. We find α 1.46 ± 0.18 for an inner collection angle of 62 mrad. Th...
Gespeichert in:
Veröffentlicht in: | Journal of physics. Conference series 2012-01, Vol.371 (1), p.12010-4 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report an experimental calibration of the exponent α, which relates intensity (I) and atomic number (Z) in HAADF-STEM imaging. The method employs size-selected Au923 and Pd923 clusters in an aberration-corrected 200 kV microscope. We find α 1.46 ± 0.18 for an inner collection angle of 62 mrad. The value of α is needed in the quantit!ative compositional analysis of, e.g., bimetallic nanostructures. The atomic structures of these two examples of size-selected magic-number clusters are also reported. |
---|---|