Evaluation of oesophageal transit velocity using the improved Demons technique

PURPOSEThis paper presents a novel method to compute oesophageal transit velocity in a direct and automatized manner by the registration of scintigraphy images. METHODSA total of 36 images from nine healthy volunteers were processed. Four dynamic image series per volunteer were acquired after a mini...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear medicine communications 2016-01, Vol.37 (1), p.87-91
Hauptverfasser: De Souza, Michele N, Xavier, Fernando E.B, Secaf, Marie, Troncon, Luiz E.A, de Oliveira, Ricardo B, Moraes, Eder R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 91
container_issue 1
container_start_page 87
container_title Nuclear medicine communications
container_volume 37
creator De Souza, Michele N
Xavier, Fernando E.B
Secaf, Marie
Troncon, Luiz E.A
de Oliveira, Ricardo B
Moraes, Eder R
description PURPOSEThis paper presents a novel method to compute oesophageal transit velocity in a direct and automatized manner by the registration of scintigraphy images. METHODSA total of 36 images from nine healthy volunteers were processed. Four dynamic image series per volunteer were acquired after a minimum 8 h fast. Each acquisition was made following the ingestion of 5 ml saline labelled with about 26 MBq (700 µCi) technetium-99m phytate in a single swallow. Between the acquisitions, another two swallows of 5 ml saline were performed to clear the oesophagus. The composite acquired files were made of 240 frames of anterior and posterior views. Each frame is the accumulate count for 250 ms.At the end of acquisitions, the images were corrected for radioactive decay, the geometric mean was computed between the anterior and posterior views and the registration of a set of subsequent images was performed. Utilizing the improved Demons technique, we obtained from the deformation field the regional resultant velocity, which is directly related to the oesophagus transit velocity. RESULTSThe mean regional resulting velocities decreases progressively from the proximal to the distal oesophageal portions and, at the proximal portion, is virtually identical to the primary peristaltic pump typical velocity. Comparison between this parameter and ‘time–activity’ curves reveals consistency in velocities obtained using both methods, for the proximal portion. CONCLUSIONApplication of the improved Demons technique, as an easy and automated method to evaluate velocities of oesophageal bolus transit, is feasible and seems to yield consistent data, particularly for the proximal oesophagus.
doi_str_mv 10.1097/MNM.0000000000000413
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1735329970</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1735329970</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3753-d6594ad91fbeb1210898be1b9c064319bbd6dbc00489eb19815de5262302aaa83</originalsourceid><addsrcrecordid>eNp9kLtOwzAUhi0EoqXwBgh5ZEmx49iJR1TKRWrLAnNkJ6eNIYlL7LTq22PUghADZznL95_Lh9AlJWNKZHozX8zH5HcllB2hIU1SFnERZ8doSGjCIiaYGKAz594CkzGRnqJBLBKecimGaDHdqLpX3tgW2yW24Oy6UitQNfadap3xeAO1LYzf4d6ZdoV9Bdg0685uoMR30NjWYQ9F1ZqPHs7RyVLVDi4OfYRe76cvk8do9vzwNLmdRQVLOYtKwWWiSkmXGjSNKclkpoFqWRCRMCq1LkWpi_BTJgMgM8pL4LGIGYmVUhkboev93HBHWOt83hhXQF2rFmzvcpoyzmIpUxLQZI8WnXWug2W-7kyjul1OSf5lMg8m878mQ-zqsKHXDZQ_oW91Acj2wNbWHjr3Xvdb6PIqqPPV_7M_AbDPf_U</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1735329970</pqid></control><display><type>article</type><title>Evaluation of oesophageal transit velocity using the improved Demons technique</title><source>MEDLINE</source><source>Journals@Ovid Ovid Autoload</source><creator>De Souza, Michele N ; Xavier, Fernando E.B ; Secaf, Marie ; Troncon, Luiz E.A ; de Oliveira, Ricardo B ; Moraes, Eder R</creator><creatorcontrib>De Souza, Michele N ; Xavier, Fernando E.B ; Secaf, Marie ; Troncon, Luiz E.A ; de Oliveira, Ricardo B ; Moraes, Eder R</creatorcontrib><description>PURPOSEThis paper presents a novel method to compute oesophageal transit velocity in a direct and automatized manner by the registration of scintigraphy images. METHODSA total of 36 images from nine healthy volunteers were processed. Four dynamic image series per volunteer were acquired after a minimum 8 h fast. Each acquisition was made following the ingestion of 5 ml saline labelled with about 26 MBq (700 µCi) technetium-99m phytate in a single swallow. Between the acquisitions, another two swallows of 5 ml saline were performed to clear the oesophagus. The composite acquired files were made of 240 frames of anterior and posterior views. Each frame is the accumulate count for 250 ms.At the end of acquisitions, the images were corrected for radioactive decay, the geometric mean was computed between the anterior and posterior views and the registration of a set of subsequent images was performed. Utilizing the improved Demons technique, we obtained from the deformation field the regional resultant velocity, which is directly related to the oesophagus transit velocity. RESULTSThe mean regional resulting velocities decreases progressively from the proximal to the distal oesophageal portions and, at the proximal portion, is virtually identical to the primary peristaltic pump typical velocity. Comparison between this parameter and ‘time–activity’ curves reveals consistency in velocities obtained using both methods, for the proximal portion. CONCLUSIONApplication of the improved Demons technique, as an easy and automated method to evaluate velocities of oesophageal bolus transit, is feasible and seems to yield consistent data, particularly for the proximal oesophagus.</description><identifier>ISSN: 0143-3636</identifier><identifier>EISSN: 1473-5628</identifier><identifier>DOI: 10.1097/MNM.0000000000000413</identifier><identifier>PMID: 26457596</identifier><language>eng</language><publisher>England: Copyright Wolters Kluwer Health, Inc. All rights reserved</publisher><subject>Adult ; Esophagus - diagnostic imaging ; Esophagus - physiology ; Female ; Gastrointestinal Transit ; Healthy Volunteers ; Humans ; Image Processing, Computer-Assisted - methods ; Male ; Middle Aged ; Radionuclide Imaging</subject><ispartof>Nuclear medicine communications, 2016-01, Vol.37 (1), p.87-91</ispartof><rights>Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3753-d6594ad91fbeb1210898be1b9c064319bbd6dbc00489eb19815de5262302aaa83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26457596$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>De Souza, Michele N</creatorcontrib><creatorcontrib>Xavier, Fernando E.B</creatorcontrib><creatorcontrib>Secaf, Marie</creatorcontrib><creatorcontrib>Troncon, Luiz E.A</creatorcontrib><creatorcontrib>de Oliveira, Ricardo B</creatorcontrib><creatorcontrib>Moraes, Eder R</creatorcontrib><title>Evaluation of oesophageal transit velocity using the improved Demons technique</title><title>Nuclear medicine communications</title><addtitle>Nucl Med Commun</addtitle><description>PURPOSEThis paper presents a novel method to compute oesophageal transit velocity in a direct and automatized manner by the registration of scintigraphy images. METHODSA total of 36 images from nine healthy volunteers were processed. Four dynamic image series per volunteer were acquired after a minimum 8 h fast. Each acquisition was made following the ingestion of 5 ml saline labelled with about 26 MBq (700 µCi) technetium-99m phytate in a single swallow. Between the acquisitions, another two swallows of 5 ml saline were performed to clear the oesophagus. The composite acquired files were made of 240 frames of anterior and posterior views. Each frame is the accumulate count for 250 ms.At the end of acquisitions, the images were corrected for radioactive decay, the geometric mean was computed between the anterior and posterior views and the registration of a set of subsequent images was performed. Utilizing the improved Demons technique, we obtained from the deformation field the regional resultant velocity, which is directly related to the oesophagus transit velocity. RESULTSThe mean regional resulting velocities decreases progressively from the proximal to the distal oesophageal portions and, at the proximal portion, is virtually identical to the primary peristaltic pump typical velocity. Comparison between this parameter and ‘time–activity’ curves reveals consistency in velocities obtained using both methods, for the proximal portion. CONCLUSIONApplication of the improved Demons technique, as an easy and automated method to evaluate velocities of oesophageal bolus transit, is feasible and seems to yield consistent data, particularly for the proximal oesophagus.</description><subject>Adult</subject><subject>Esophagus - diagnostic imaging</subject><subject>Esophagus - physiology</subject><subject>Female</subject><subject>Gastrointestinal Transit</subject><subject>Healthy Volunteers</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted - methods</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Radionuclide Imaging</subject><issn>0143-3636</issn><issn>1473-5628</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kLtOwzAUhi0EoqXwBgh5ZEmx49iJR1TKRWrLAnNkJ6eNIYlL7LTq22PUghADZznL95_Lh9AlJWNKZHozX8zH5HcllB2hIU1SFnERZ8doSGjCIiaYGKAz594CkzGRnqJBLBKecimGaDHdqLpX3tgW2yW24Oy6UitQNfadap3xeAO1LYzf4d6ZdoV9Bdg0685uoMR30NjWYQ9F1ZqPHs7RyVLVDi4OfYRe76cvk8do9vzwNLmdRQVLOYtKwWWiSkmXGjSNKclkpoFqWRCRMCq1LkWpi_BTJgMgM8pL4LGIGYmVUhkboev93HBHWOt83hhXQF2rFmzvcpoyzmIpUxLQZI8WnXWug2W-7kyjul1OSf5lMg8m878mQ-zqsKHXDZQ_oW91Acj2wNbWHjr3Xvdb6PIqqPPV_7M_AbDPf_U</recordid><startdate>201601</startdate><enddate>201601</enddate><creator>De Souza, Michele N</creator><creator>Xavier, Fernando E.B</creator><creator>Secaf, Marie</creator><creator>Troncon, Luiz E.A</creator><creator>de Oliveira, Ricardo B</creator><creator>Moraes, Eder R</creator><general>Copyright Wolters Kluwer Health, Inc. All rights reserved</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201601</creationdate><title>Evaluation of oesophageal transit velocity using the improved Demons technique</title><author>De Souza, Michele N ; Xavier, Fernando E.B ; Secaf, Marie ; Troncon, Luiz E.A ; de Oliveira, Ricardo B ; Moraes, Eder R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3753-d6594ad91fbeb1210898be1b9c064319bbd6dbc00489eb19815de5262302aaa83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Adult</topic><topic>Esophagus - diagnostic imaging</topic><topic>Esophagus - physiology</topic><topic>Female</topic><topic>Gastrointestinal Transit</topic><topic>Healthy Volunteers</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted - methods</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Radionuclide Imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>De Souza, Michele N</creatorcontrib><creatorcontrib>Xavier, Fernando E.B</creatorcontrib><creatorcontrib>Secaf, Marie</creatorcontrib><creatorcontrib>Troncon, Luiz E.A</creatorcontrib><creatorcontrib>de Oliveira, Ricardo B</creatorcontrib><creatorcontrib>Moraes, Eder R</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Nuclear medicine communications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>De Souza, Michele N</au><au>Xavier, Fernando E.B</au><au>Secaf, Marie</au><au>Troncon, Luiz E.A</au><au>de Oliveira, Ricardo B</au><au>Moraes, Eder R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of oesophageal transit velocity using the improved Demons technique</atitle><jtitle>Nuclear medicine communications</jtitle><addtitle>Nucl Med Commun</addtitle><date>2016-01</date><risdate>2016</risdate><volume>37</volume><issue>1</issue><spage>87</spage><epage>91</epage><pages>87-91</pages><issn>0143-3636</issn><eissn>1473-5628</eissn><abstract>PURPOSEThis paper presents a novel method to compute oesophageal transit velocity in a direct and automatized manner by the registration of scintigraphy images. METHODSA total of 36 images from nine healthy volunteers were processed. Four dynamic image series per volunteer were acquired after a minimum 8 h fast. Each acquisition was made following the ingestion of 5 ml saline labelled with about 26 MBq (700 µCi) technetium-99m phytate in a single swallow. Between the acquisitions, another two swallows of 5 ml saline were performed to clear the oesophagus. The composite acquired files were made of 240 frames of anterior and posterior views. Each frame is the accumulate count for 250 ms.At the end of acquisitions, the images were corrected for radioactive decay, the geometric mean was computed between the anterior and posterior views and the registration of a set of subsequent images was performed. Utilizing the improved Demons technique, we obtained from the deformation field the regional resultant velocity, which is directly related to the oesophagus transit velocity. RESULTSThe mean regional resulting velocities decreases progressively from the proximal to the distal oesophageal portions and, at the proximal portion, is virtually identical to the primary peristaltic pump typical velocity. Comparison between this parameter and ‘time–activity’ curves reveals consistency in velocities obtained using both methods, for the proximal portion. CONCLUSIONApplication of the improved Demons technique, as an easy and automated method to evaluate velocities of oesophageal bolus transit, is feasible and seems to yield consistent data, particularly for the proximal oesophagus.</abstract><cop>England</cop><pub>Copyright Wolters Kluwer Health, Inc. All rights reserved</pub><pmid>26457596</pmid><doi>10.1097/MNM.0000000000000413</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0143-3636
ispartof Nuclear medicine communications, 2016-01, Vol.37 (1), p.87-91
issn 0143-3636
1473-5628
language eng
recordid cdi_proquest_miscellaneous_1735329970
source MEDLINE; Journals@Ovid Ovid Autoload
subjects Adult
Esophagus - diagnostic imaging
Esophagus - physiology
Female
Gastrointestinal Transit
Healthy Volunteers
Humans
Image Processing, Computer-Assisted - methods
Male
Middle Aged
Radionuclide Imaging
title Evaluation of oesophageal transit velocity using the improved Demons technique
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-12T18%3A03%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20oesophageal%20transit%20velocity%20using%20the%20improved%20Demons%20technique&rft.jtitle=Nuclear%20medicine%20communications&rft.au=De%20Souza,%20Michele%20N&rft.date=2016-01&rft.volume=37&rft.issue=1&rft.spage=87&rft.epage=91&rft.pages=87-91&rft.issn=0143-3636&rft.eissn=1473-5628&rft_id=info:doi/10.1097/MNM.0000000000000413&rft_dat=%3Cproquest_cross%3E1735329970%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1735329970&rft_id=info:pmid/26457596&rfr_iscdi=true