Evaluation of oesophageal transit velocity using the improved Demons technique

PURPOSEThis paper presents a novel method to compute oesophageal transit velocity in a direct and automatized manner by the registration of scintigraphy images. METHODSA total of 36 images from nine healthy volunteers were processed. Four dynamic image series per volunteer were acquired after a mini...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear medicine communications 2016-01, Vol.37 (1), p.87-91
Hauptverfasser: De Souza, Michele N, Xavier, Fernando E.B, Secaf, Marie, Troncon, Luiz E.A, de Oliveira, Ricardo B, Moraes, Eder R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PURPOSEThis paper presents a novel method to compute oesophageal transit velocity in a direct and automatized manner by the registration of scintigraphy images. METHODSA total of 36 images from nine healthy volunteers were processed. Four dynamic image series per volunteer were acquired after a minimum 8 h fast. Each acquisition was made following the ingestion of 5 ml saline labelled with about 26 MBq (700 µCi) technetium-99m phytate in a single swallow. Between the acquisitions, another two swallows of 5 ml saline were performed to clear the oesophagus. The composite acquired files were made of 240 frames of anterior and posterior views. Each frame is the accumulate count for 250 ms.At the end of acquisitions, the images were corrected for radioactive decay, the geometric mean was computed between the anterior and posterior views and the registration of a set of subsequent images was performed. Utilizing the improved Demons technique, we obtained from the deformation field the regional resultant velocity, which is directly related to the oesophagus transit velocity. RESULTSThe mean regional resulting velocities decreases progressively from the proximal to the distal oesophageal portions and, at the proximal portion, is virtually identical to the primary peristaltic pump typical velocity. Comparison between this parameter and ‘time–activity’ curves reveals consistency in velocities obtained using both methods, for the proximal portion. CONCLUSIONApplication of the improved Demons technique, as an easy and automated method to evaluate velocities of oesophageal bolus transit, is feasible and seems to yield consistent data, particularly for the proximal oesophagus.
ISSN:0143-3636
1473-5628
DOI:10.1097/MNM.0000000000000413