Three-Corner Arthrodesis With Scaphoid and Triquetrum Excision for Wrist Arthritis

Purpose To report the clinical and radiographic results of a consecutive series of patients who underwent the 3-corner arthrodesis (3CA) (arthrodesis of capitate, hamate, and lunate with scaphoid and triquetrum excision) procedure for wrist arthritis. Methods This was a retrospective study of 30 con...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of hand surgery (American ed.) 2015-11, Vol.40 (11), p.2176-2182
Hauptverfasser: Delattre, Olivier, MD, PhD, Goulon, Gilles, MD, Vogels, Jérôme, MD, Wavreille, Guillaume, MD, Lasnier, Arthur, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose To report the clinical and radiographic results of a consecutive series of patients who underwent the 3-corner arthrodesis (3CA) (arthrodesis of capitate, hamate, and lunate with scaphoid and triquetrum excision) procedure for wrist arthritis. Methods This was a retrospective study of 30 consecutive patients who underwent a 3CA between 1994 and 2008. The indications were painful wrist osteoarthritis due to stage 2 or 3 scapholunate advanced collapse, scaphoid nonunion advanced collapse, or scaphoid chondrocalcinosis advanced collapse wrists. The clinical assessment consisted of range of motion, grip strength, and the Disabilities of the Arm, Shoulder, and Hand and Patient-Rated Wrist Evaluation scores. The radiographic assessment parameters consisted of bone fusion, carpal height and translation, lunate tilt, and appearance of the radiolunate joint space. Results The average follow-up was 6 years (± 4 years). The arthrodesis was performed with staples, 2 screws, or a plate and screws. Grip strength was 72% of the contralateral side. The mean range of motion in flexion-extension arc and ulnar-radial deviation arc was 70° and 36°, respectively. The mean Disabilities of the Arm, Shoulder, and Hand and the Patient-Rated Wrist Evaluation scores were 17 (± 11) and 22 (± 24), respectively. The fusion incidence was 90% (27 of 30). The mean difference of radiolunate angle on preoperative and postoperative radiographs was 8° (16°–8° in dorsal direction). The radiolunate joint space had narrowed in 1 patient. Six surgical revisions (20%) were necessary owing to dorsal pain in patients operated using plates, staples, or excessively long screws. Conclusions Three-corner arthrodesis results are comparable with 4-corner arthrodesis and proximal row carpectomy. We feel that it is simpler technically than 4-corner arthrodesis. Although 3CA is more complex than proximal row carpectomy, it preserves the native radiolunate joint. Complications that can be attributed to the dorsal fixation hardware (particularly staples and plates) were noteworthy. Type of study/level of evidence Therapeutic IV.
ISSN:0363-5023
1531-6564
DOI:10.1016/j.jhsa.2015.07.032