The Measurement of Dissolved Organic and Particulate Carbon in Seawater

A method is described for the rapid determination of dissolved organic carbon in seawater in concentrations between 0.1 and 20 mg/liter. The oxidation is carried out in sealed glass ampoules using K2S 2O 2as an oxidizing agent after the sample has been freed of inorganic carbon. The resulting CO2is...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Limnology and oceanography 1964-01, Vol.9 (1), p.138-142
Hauptverfasser: Menzel, David W., Vaccaro, Ralph F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A method is described for the rapid determination of dissolved organic carbon in seawater in concentrations between 0.1 and 20 mg/liter. The oxidation is carried out in sealed glass ampoules using K2S 2O 2as an oxidizing agent after the sample has been freed of inorganic carbon. The resulting CO2is passed through a nondispersive infrared analyzer using nitrogen as a carrier an the signal output of the analyzer recorded. Using appropriate calibration curves, the carbon content is determined from the height of the peak. Approximately 100 samples can be analyzed in a single day with a precisio of ± 0.1 mg/liter using a sample volume of 5 ml. A companion method is described for the determination of particulate carbon by high-temperature combustion after concentration of the sample on a glass-filber filter. The precision of this method is ± 10 μ g C in a range of 0-500 μ g C. Approximately six samples can be analyzed in an hour.
ISSN:0024-3590