Cost-effective flow injection amperometric system with metal nanoparticle loaded carbon nanotube modified screen printed carbon electrode for sensitive determination of hydrogen peroxide

Various metal nanoparticles (NPs) decorated on carbon nanotube (CNT) was modified on the home-made screen printed carbon electrode (SPCE) in order to enhances sensitivity of hydrogen peroxide (H2O2) determination. The simple casting method was used for the electrode modification. The monometallic an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2015-11, Vol.144, p.868-874
Hauptverfasser: Reanpang, Preeyaporn, Themsirimongkon, Suwaphid, Saipanya, Surin, Chailapakul, Orawon, Jakmunee, Jaroon
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Various metal nanoparticles (NPs) decorated on carbon nanotube (CNT) was modified on the home-made screen printed carbon electrode (SPCE) in order to enhances sensitivity of hydrogen peroxide (H2O2) determination. The simple casting method was used for the electrode modification. The monometallic and bimetallic NPs modified electrodes were investigated for their electrochemical properties for H2O2 reduction. The Pd-CNT/SPCE is appropriated to measure the H2O2 reduction at a potential of −0.3V, then this modified electrode was incorporated with a home-made flow through cell and applied in a simple flow injection amperometry (FI-Amp). Some parameters influencing the resulted modified electrode and the FI-Amp system were studied. The proposed detection system was able to detect H2O2 in the range of 0.1–1.0mM, with detection limit of 20µM. Relative standard deviation for 100 replicated injections of 0.6mM H2O2 was 2.3%. The reproducibility of 6 electrodes preparing in 3 different lots was 8.2%. It was demonstrated for determination of H2O2 in disinfectant, hair colorant and milk samples. Recoveries in the range of 90–109% were observed. The developed system provided high stability, good repeatability, high sample throughput and low reagent consumption. [Display omitted] •Home-made SPCE was modified with various metal NPs–CNT for sensitive H2O2 detection.•The Pd-CNT/SPCE exhibited catalytic activity on H2O2 reduction.•The developed electrode was applied for H2O2 determination in FI amperometric system.•A low cost home-made flow through cell for SPCE was fabricated.•The FI amperometric system shows good sensitivity, stability, repeatability and simplicity.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2015.07.041