Investigation of wide-aperture plasmonic detectors by a tightly focused terahertz beam
Terahertz response of wide-aperture plasmonic detectors is studied experimentally by using a focused terahertz radiation with frequencies 1.63, 1.89 and 2.55 THz. Two different types of plasmonic detector have been investigated: (i) field-effect transistor (FET) with a grating-gate of large (2×2 mm2...
Gespeichert in:
Veröffentlicht in: | Journal of physics. Conference series 2014-01, Vol.486 (1), p.12013-5 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Terahertz response of wide-aperture plasmonic detectors is studied experimentally by using a focused terahertz radiation with frequencies 1.63, 1.89 and 2.55 THz. Two different types of plasmonic detector have been investigated: (i) field-effect transistor (FET) with a grating-gate of large (2×2 mm2) area and (ii) FET with a single gate and ohmic contacts forming a bow-tie antenna. By raster scanning the detector area by using a tightly focused terahertz beam, we studied the contribution of individual parts of the detector to the total detection response and we determined the effective area of the detector structures. |
---|---|
ISSN: | 1742-6596 1742-6588 1742-6596 |
DOI: | 10.1088/1742-6596/486/1/012013 |