ITER divertor heat transfer system and loss of vacuum accident sequence analyses overview

The paper presents the analyses performed by the European Union ITER Home Team for five ITER reference accident sequences: two loss of flow and two loss of coolant accidents on the divertor primary heat transfer system, and one loss of vacuum accident. Tritium and activated materials ground and stac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Fusion engineering and design 1998-09, Vol.42 (1), p.95-101
Hauptverfasser: Cambi, G., Porfiri, M.T., Jahn, H., Cepraga, D.G., Bartels, H.-W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The paper presents the analyses performed by the European Union ITER Home Team for five ITER reference accident sequences: two loss of flow and two loss of coolant accidents on the divertor primary heat transfer system, and one loss of vacuum accident. Tritium and activated materials ground and stack environmental releases have been evaluated for each one of the accident sequences, up to 7 days from the accident start. The ATHENA and the INTRA codes are used for the accident transient thermal–hydraulic analysis and for the containment response to coolant leaks, respectively. The NAUA Mod 5M code has been used to assess the radioactive material transport, deposition and leakage inside and through the containment.
ISSN:0920-3796
1873-7196
DOI:10.1016/S0920-3796(98)00090-8