An analysis of normative data on the knee rotatory profile and the usefulness of the Rotatometer, a new instrument for measuring tibiofemoral rotation: the reliability of the knee Rotatometer

Purpose This study proposes a simple and noninvasive instrument called the “Rotatometer” to measure tibiofemoral rotation and investigates its clinical applicability to the assessment of static rotational knee laxity. Methods The degree of tibiofemoral rotation was measured for a sample of 94 health...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA sports traumatology, arthroscopy : official journal of the ESSKA, 2015-09, Vol.23 (9), p.2727-2733
Hauptverfasser: Chung, Ju Hwan, Ryu, Keun Jung, Lee, Dong Hoon, Yoon, Kyung Ho, Park, Yang Woo, Kim, Hyung Jong, Kim, Jae Hwa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose This study proposes a simple and noninvasive instrument called the “Rotatometer” to measure tibiofemoral rotation and investigates its clinical applicability to the assessment of static rotational knee laxity. Methods The degree of tibiofemoral rotation was measured for a sample of 94 healthy volunteers with 188 knees by using the Rotatometer. The measurement was made by two independent and blinded examiners in three sessions at one-month intervals. The normative rotational profile and its relationship with gender and age were evaluated, and inter-observer reliability and intra-observer reliability were calculated. Results Males showed 62° ± 5° of external rotation, whereas females, 64° ± 5°. Males showed 44° ± 5° of internal rotation, whereas females, 49° ± 4°. Females showed significantly higher degrees of rotation than males. Tibiofemoral rotation was not correlated with age, and external rotation and internal rotation had a moderate positive relationship. Inter-observer reliability ranged from 0.84 to 0.91 for external rotation and 0.90 to 0.95 for internal rotation, and intra-observer reliability ranged from 0.69 to 0.89 for external rotation and 0.87 to 0.95 for internal rotation. Conclusions The results suggest the Rotatometer to be a simple and noninvasive device with high inter- and intra-observer reliability. The device can provide a normative rotational profile for reference purposes and thus can be used to determine the preoperative and postoperative rotational status of knees with anterior cruciate ligament injuries and compare results from different reconstruction techniques. Level of evidence Diagnostic study, Level III.
ISSN:0942-2056
1433-7347
DOI:10.1007/s00167-014-3039-9