Evaluation of High-Rate Clarification for Wet-Weather-Only Treatment Facilities
High-rate clarification (HRC) processes are well suited for enhanced primary treatment of wet-weather flows in combined sewer systems. Suspended solids removal in excess of 75% of influent concentrations can be achieved consistently. Chemical oxygen demand and five-day biochemical oxygen demand remo...
Gespeichert in:
Veröffentlicht in: | Water environment research 2004-09, Vol.76 (5), p.474-480 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | High-rate clarification (HRC) processes are well suited for enhanced primary treatment of wet-weather flows in combined sewer systems. Suspended solids removal in excess of 75% of influent concentrations can be achieved consistently. Chemical oxygen demand and five-day biochemical oxygen demand removal are better than 60%. However, although optimal treatment could be achieved in a matter of minutes when the units were started full, a delay of up to one-half hour was observed when the units were started empty. Operational strategies that minimize this effect need to be developed in full-scale tests before HRC processes can be implemented with confidence in wet-weather-only facilities. |
---|---|
ISSN: | 1061-4303 1554-7531 |
DOI: | 10.2175/106143004X151563 |