Evaluation of the radiation parameters of the Gamma-4 electrophysical facility

This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was me...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of applied mechanics and technical physics 2015-01, Vol.56 (1), p.67-71
Hauptverfasser: Zav’yalov, N. V., Gordeev, V. S., Puchagin, S. Yu, Mozgovoi, A. L., Grishin, A. V., Strabykin, K. V., Mansurov, D. O., Moiseevskikh, M. A., Berdnikov, E. S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 71
container_issue 1
container_start_page 67
container_title Journal of applied mechanics and technical physics
container_volume 56
creator Zav’yalov, N. V.
Gordeev, V. S.
Puchagin, S. Yu
Mozgovoi, A. L.
Grishin, A. V.
Strabykin, K. V.
Mansurov, D. O.
Moiseevskikh, M. A.
Berdnikov, E. S.
description This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was measured at a distance of 20, 30, and 60 cm from the accelerator target. It is shown that the experimental data correspond to the radiation field of a point cosine source with a relative error of 13%. The spatial distribution of the bremsstrahlung exposure dose of the Gamma-4 facility was reconstructed taking into account the spatial orientation of the irradiators. The bremsstrahlung exposure doses at a distance of 15 cm from the modules targets are presented.
doi_str_mv 10.1134/S0021894415010113
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1709738628</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1709738628</sourcerecordid><originalsourceid>FETCH-LOGICAL-c273t-cc57d1cb0114db10bce8f594ecac9fd0f44875abfaa82a637d76f3525d27deb73</originalsourceid><addsrcrecordid>eNp9UMtKxDAUDaLgOPoB7rp0U82rk3QpwzgKgy7UdblNEydD2tQkFfr3dqiuBFcXzot7DkLXBN8SwvjdK8aUyJJzUmCCJ-gELUghWC5XFJ-ixZHOj_w5uojxgDEuJREL9Lz5AjdAsr7LvMnSXmcBGjsDPQRoddIh_nJbaFvIeaadVin4fj9Gq8BlBpR1No2X6MyAi_rq5y7R-8Pmbf2Y7162T-v7Xa6oYClXqhANUfX0KG9qgmulpSlKrhWo0jTYcC5FAbUBkBRWTDRiZVhBi4aKRteCLdHNnNsH_znomKrWRqWdg077IVZE4FKwqbucpGSWquBjDNpUfbAthLEiuDpuV_3ZbvLQ2RMnbfehQ3XwQ-imRv-YvgHDsHFE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1709738628</pqid></control><display><type>article</type><title>Evaluation of the radiation parameters of the Gamma-4 electrophysical facility</title><source>SpringerLink Journals - AutoHoldings</source><creator>Zav’yalov, N. V. ; Gordeev, V. S. ; Puchagin, S. Yu ; Mozgovoi, A. L. ; Grishin, A. V. ; Strabykin, K. V. ; Mansurov, D. O. ; Moiseevskikh, M. A. ; Berdnikov, E. S.</creator><creatorcontrib>Zav’yalov, N. V. ; Gordeev, V. S. ; Puchagin, S. Yu ; Mozgovoi, A. L. ; Grishin, A. V. ; Strabykin, K. V. ; Mansurov, D. O. ; Moiseevskikh, M. A. ; Berdnikov, E. S.</creatorcontrib><description>This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was measured at a distance of 20, 30, and 60 cm from the accelerator target. It is shown that the experimental data correspond to the radiation field of a point cosine source with a relative error of 13%. The spatial distribution of the bremsstrahlung exposure dose of the Gamma-4 facility was reconstructed taking into account the spatial orientation of the irradiators. The bremsstrahlung exposure doses at a distance of 15 cm from the modules targets are presented.</description><identifier>ISSN: 0021-8944</identifier><identifier>EISSN: 1573-8620</identifier><identifier>DOI: 10.1134/S0021894415010113</identifier><language>eng</language><publisher>Moscow: Pleiades Publishing</publisher><subject>Accelerators ; Applications of Mathematics ; Bremsstrahlung ; Classical and Continuum Physics ; Classical Mechanics ; Errors ; Exposure ; Fluid- and Aerodynamics ; Mathematical Modeling and Industrial Mathematics ; Mechanical Engineering ; Modules ; Orientation ; Physics ; Physics and Astronomy ; Shot ; Spatial distribution</subject><ispartof>Journal of applied mechanics and technical physics, 2015-01, Vol.56 (1), p.67-71</ispartof><rights>Pleiades Publishing, Ltd. 2015</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1134/S0021894415010113$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1134/S0021894415010113$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids></links><search><creatorcontrib>Zav’yalov, N. V.</creatorcontrib><creatorcontrib>Gordeev, V. S.</creatorcontrib><creatorcontrib>Puchagin, S. Yu</creatorcontrib><creatorcontrib>Mozgovoi, A. L.</creatorcontrib><creatorcontrib>Grishin, A. V.</creatorcontrib><creatorcontrib>Strabykin, K. V.</creatorcontrib><creatorcontrib>Mansurov, D. O.</creatorcontrib><creatorcontrib>Moiseevskikh, M. A.</creatorcontrib><creatorcontrib>Berdnikov, E. S.</creatorcontrib><title>Evaluation of the radiation parameters of the Gamma-4 electrophysical facility</title><title>Journal of applied mechanics and technical physics</title><addtitle>J Appl Mech Tech Phy</addtitle><description>This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was measured at a distance of 20, 30, and 60 cm from the accelerator target. It is shown that the experimental data correspond to the radiation field of a point cosine source with a relative error of 13%. The spatial distribution of the bremsstrahlung exposure dose of the Gamma-4 facility was reconstructed taking into account the spatial orientation of the irradiators. The bremsstrahlung exposure doses at a distance of 15 cm from the modules targets are presented.</description><subject>Accelerators</subject><subject>Applications of Mathematics</subject><subject>Bremsstrahlung</subject><subject>Classical and Continuum Physics</subject><subject>Classical Mechanics</subject><subject>Errors</subject><subject>Exposure</subject><subject>Fluid- and Aerodynamics</subject><subject>Mathematical Modeling and Industrial Mathematics</subject><subject>Mechanical Engineering</subject><subject>Modules</subject><subject>Orientation</subject><subject>Physics</subject><subject>Physics and Astronomy</subject><subject>Shot</subject><subject>Spatial distribution</subject><issn>0021-8944</issn><issn>1573-8620</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9UMtKxDAUDaLgOPoB7rp0U82rk3QpwzgKgy7UdblNEydD2tQkFfr3dqiuBFcXzot7DkLXBN8SwvjdK8aUyJJzUmCCJ-gELUghWC5XFJ-ixZHOj_w5uojxgDEuJREL9Lz5AjdAsr7LvMnSXmcBGjsDPQRoddIh_nJbaFvIeaadVin4fj9Gq8BlBpR1No2X6MyAi_rq5y7R-8Pmbf2Y7162T-v7Xa6oYClXqhANUfX0KG9qgmulpSlKrhWo0jTYcC5FAbUBkBRWTDRiZVhBi4aKRteCLdHNnNsH_znomKrWRqWdg077IVZE4FKwqbucpGSWquBjDNpUfbAthLEiuDpuV_3ZbvLQ2RMnbfehQ3XwQ-imRv-YvgHDsHFE</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Zav’yalov, N. V.</creator><creator>Gordeev, V. S.</creator><creator>Puchagin, S. Yu</creator><creator>Mozgovoi, A. L.</creator><creator>Grishin, A. V.</creator><creator>Strabykin, K. V.</creator><creator>Mansurov, D. O.</creator><creator>Moiseevskikh, M. A.</creator><creator>Berdnikov, E. S.</creator><general>Pleiades Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20150101</creationdate><title>Evaluation of the radiation parameters of the Gamma-4 electrophysical facility</title><author>Zav’yalov, N. V. ; Gordeev, V. S. ; Puchagin, S. Yu ; Mozgovoi, A. L. ; Grishin, A. V. ; Strabykin, K. V. ; Mansurov, D. O. ; Moiseevskikh, M. A. ; Berdnikov, E. S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c273t-cc57d1cb0114db10bce8f594ecac9fd0f44875abfaa82a637d76f3525d27deb73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Accelerators</topic><topic>Applications of Mathematics</topic><topic>Bremsstrahlung</topic><topic>Classical and Continuum Physics</topic><topic>Classical Mechanics</topic><topic>Errors</topic><topic>Exposure</topic><topic>Fluid- and Aerodynamics</topic><topic>Mathematical Modeling and Industrial Mathematics</topic><topic>Mechanical Engineering</topic><topic>Modules</topic><topic>Orientation</topic><topic>Physics</topic><topic>Physics and Astronomy</topic><topic>Shot</topic><topic>Spatial distribution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zav’yalov, N. V.</creatorcontrib><creatorcontrib>Gordeev, V. S.</creatorcontrib><creatorcontrib>Puchagin, S. Yu</creatorcontrib><creatorcontrib>Mozgovoi, A. L.</creatorcontrib><creatorcontrib>Grishin, A. V.</creatorcontrib><creatorcontrib>Strabykin, K. V.</creatorcontrib><creatorcontrib>Mansurov, D. O.</creatorcontrib><creatorcontrib>Moiseevskikh, M. A.</creatorcontrib><creatorcontrib>Berdnikov, E. S.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of applied mechanics and technical physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zav’yalov, N. V.</au><au>Gordeev, V. S.</au><au>Puchagin, S. Yu</au><au>Mozgovoi, A. L.</au><au>Grishin, A. V.</au><au>Strabykin, K. V.</au><au>Mansurov, D. O.</au><au>Moiseevskikh, M. A.</au><au>Berdnikov, E. S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the radiation parameters of the Gamma-4 electrophysical facility</atitle><jtitle>Journal of applied mechanics and technical physics</jtitle><stitle>J Appl Mech Tech Phy</stitle><date>2015-01-01</date><risdate>2015</risdate><volume>56</volume><issue>1</issue><spage>67</spage><epage>71</epage><pages>67-71</pages><issn>0021-8944</issn><eissn>1573-8620</eissn><abstract>This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was measured at a distance of 20, 30, and 60 cm from the accelerator target. It is shown that the experimental data correspond to the radiation field of a point cosine source with a relative error of 13%. The spatial distribution of the bremsstrahlung exposure dose of the Gamma-4 facility was reconstructed taking into account the spatial orientation of the irradiators. The bremsstrahlung exposure doses at a distance of 15 cm from the modules targets are presented.</abstract><cop>Moscow</cop><pub>Pleiades Publishing</pub><doi>10.1134/S0021894415010113</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-8944
ispartof Journal of applied mechanics and technical physics, 2015-01, Vol.56 (1), p.67-71
issn 0021-8944
1573-8620
language eng
recordid cdi_proquest_miscellaneous_1709738628
source SpringerLink Journals - AutoHoldings
subjects Accelerators
Applications of Mathematics
Bremsstrahlung
Classical and Continuum Physics
Classical Mechanics
Errors
Exposure
Fluid- and Aerodynamics
Mathematical Modeling and Industrial Mathematics
Mechanical Engineering
Modules
Orientation
Physics
Physics and Astronomy
Shot
Spatial distribution
title Evaluation of the radiation parameters of the Gamma-4 electrophysical facility
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T07%3A00%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20radiation%20parameters%20of%20the%20Gamma-4%20electrophysical%20facility&rft.jtitle=Journal%20of%20applied%20mechanics%20and%20technical%20physics&rft.au=Zav%E2%80%99yalov,%20N.%20V.&rft.date=2015-01-01&rft.volume=56&rft.issue=1&rft.spage=67&rft.epage=71&rft.pages=67-71&rft.issn=0021-8944&rft.eissn=1573-8620&rft_id=info:doi/10.1134/S0021894415010113&rft_dat=%3Cproquest_cross%3E1709738628%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1709738628&rft_id=info:pmid/&rfr_iscdi=true