Evaluation of the radiation parameters of the Gamma-4 electrophysical facility

This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was me...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of applied mechanics and technical physics 2015-01, Vol.56 (1), p.67-71
Hauptverfasser: Zav’yalov, N. V., Gordeev, V. S., Puchagin, S. Yu, Mozgovoi, A. L., Grishin, A. V., Strabykin, K. V., Mansurov, D. O., Moiseevskikh, M. A., Berdnikov, E. S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was measured at a distance of 20, 30, and 60 cm from the accelerator target. It is shown that the experimental data correspond to the radiation field of a point cosine source with a relative error of 13%. The spatial distribution of the bremsstrahlung exposure dose of the Gamma-4 facility was reconstructed taking into account the spatial orientation of the irradiators. The bremsstrahlung exposure doses at a distance of 15 cm from the modules targets are presented.
ISSN:0021-8944
1573-8620
DOI:10.1134/S0021894415010113