Disk magnetocumulative generator with an explosive opening switch
This paper presents the results of tests of a facility based on a ten-element disk magnetocumulative generator and an explosive opening switch. A current of 10 MA with a characteristic rise time of ≈0.5 µs was obtained by breaking a circuit with a current of 18 MA in a load with an inductance of 16...
Gespeichert in:
Veröffentlicht in: | Journal of applied mechanics and technical physics 2015-01, Vol.56 (1), p.16-21 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper presents the results of tests of a facility based on a ten-element disk magnetocumulative generator and an explosive opening switch. A current of 10 MA with a characteristic rise time of ≈0.5 µs was obtained by breaking a circuit with a current of 18 MA in a load with an inductance of 16 nH, which is equivalent to the inductance of the chamber with a multiwire liner. |
---|---|