Movements of the double-lumen endotracheal tube due to lateral position with head rotation and tube fixation: a Thiel-embalmed cadaver study
Purpose Following successful double-lumen endotracheal tube (DLT) insertion for pulmonary surgery, the body position of a patient is changed from supine to lateral. This change occasionally leads to the malposition of the DLT and difficulty in differential lung ventilation. Methods In this study, we...
Gespeichert in:
Veröffentlicht in: | Surgical and radiologic anatomy (English ed.) 2015-09, Vol.37 (7), p.841-844 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
Following successful double-lumen endotracheal tube (DLT) insertion for pulmonary surgery, the body position of a patient is changed from supine to lateral. This change occasionally leads to the malposition of the DLT and difficulty in differential lung ventilation.
Methods
In this study, we investigated movements of the DLT induced by change in body position from supine to lateral, using Thiel-embalmed cadavers. Thiel-embalmed cadavers retain full flexibility of the body and preservation of natural colours, using novel preservation techniques. After the tip of the DLT was directly fixed with forceps at the appropriate position in the bronchus, the DLT depth was measured at the lip in supine and lateral positions.
Results
The depth of DLT insertion measured at the lip in right (25.2 ± 0.3 cm; mean ± SEM) and left (25.1 ± 0.3 cm) lateral positions was significantly increased compared to the supine position (24.7 ± 0.3 cm).
Conclusions
We recommend that the depth of DLT insertion should be advanced by approximately 0.5 cm from the best position, before changing from the supine to lateral position. |
---|---|