Near-Infrared Spectroscopy Hemoglobin Index Measurement During Fluid Challenge: A Prospective Study in Cardiac Surgery Patients

Objective Little is known about changes in near-infrared spectroscopy-derived tissue hemoglobin index (HbI). The authors tested the hypothesis that absolute values and changes in brain hemoglobin index (HbIb ) and skeletal muscle hemoglobin index (HbIm ) could differ from the reference arterial hemo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cardiothoracic and vascular anesthesia 2015-08, Vol.29 (4), p.924-929
Hauptverfasser: Rebet, Olivier, MD, Fischer, Marc-Olivier, MD, Zamparini, Guillaume, MD, Gérard, Jean-Louis, MD, Fellahi, Jean-Luc, MD, PhD, Hanouz, Jean-Luc, MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective Little is known about changes in near-infrared spectroscopy-derived tissue hemoglobin index (HbI). The authors tested the hypothesis that absolute values and changes in brain hemoglobin index (HbIb ) and skeletal muscle hemoglobin index (HbIm ) could differ from the reference arterial hemoglobin (Hb) during fluid challenge. Design A prospective, monocenter observational study. Setting A 16-bed cardiac surgical intensive care unit in a teaching university hospital. Participants Fifty consecutive adult patients. Interventions Investigation before and after a fluid challenge. Measurements and Main Results Simultaneous comparative Hb, HbIb and HbIm data points were collected from a blood-gas analyzer and the EQUANOX device (Nonin Medical Inc., Plymouth, MN). Correlations were determined by linear regression. No significant relationship was found between absolute values of Hb and HbIb before ( R 2 = 0.04, p = 0.627) and after ( R 2 = 0.00006, p = 0.956) fluid challenge. No significant relationship was found between absolute values of Hb and HbIm before ( R 2 = 0.030, p = 0.226) and after ( R 2 = 0.05, p = 0.117) the fluid challenge. No significant relationship was found between changes in Hb and HbIb ( R 2 = 0.26, p = 0.263) and between changes in Hb and HbIm ( R 2 = 0.001, p = 0.801) after the fluid challenge. Bland-Altman analysis showed a poor concordance between changes in Hb and HbIb , and changes in Hb and HbIm, with large limits of agreement. Conclusions HbIb and HbIm cannot be used to provide continuous noninvasive estimation of Hb, and trends in HbIb and HbIm cannot be considered as noninvasive surrogates for the trend in Hb after cardiac surgery.
ISSN:1053-0770
1532-8422
DOI:10.1053/j.jvca.2015.01.013