Hybridoma perfusion system using a sedimentation device

A novel sedimentation method with a spiral decanter was utilized with a bioreactor for propagation of hybridoma cells at high densities. The live cell concentration was increased and cell lysis was greatly reduced in this system compared to a tangential flow hollow fiber perfusion system. The specif...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biotechnology techniques 1995-11, Vol.9 (11), p.837-842
Hauptverfasser: LAPORTE, T. L, SHEVITZ, J, KIM, Y, WANS, S. S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A novel sedimentation method with a spiral decanter was utilized with a bioreactor for propagation of hybridoma cells at high densities. The live cell concentration was increased and cell lysis was greatly reduced in this system compared to a tangential flow hollow fiber perfusion system. The specific monoclonal antibody productivity was higher than that obtained using a hollow fiber perfusion system or in a batch culture. Cell specific productivity usually declined over time in long term experiments. The use of the sedimentation device eliminated progressive deterioration of reactor performance usually associated with a perfusion device.
ISSN:0951-208X
1573-6784
DOI:10.1007/BF00159411