Hybridoma perfusion system using a sedimentation device
A novel sedimentation method with a spiral decanter was utilized with a bioreactor for propagation of hybridoma cells at high densities. The live cell concentration was increased and cell lysis was greatly reduced in this system compared to a tangential flow hollow fiber perfusion system. The specif...
Gespeichert in:
Veröffentlicht in: | Biotechnology techniques 1995-11, Vol.9 (11), p.837-842 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A novel sedimentation method with a spiral decanter was utilized with a bioreactor for propagation of hybridoma cells at high densities. The live cell concentration was increased and cell lysis was greatly reduced in this system compared to a tangential flow hollow fiber perfusion system. The specific monoclonal antibody productivity was higher than that obtained using a hollow fiber perfusion system or in a batch culture. Cell specific productivity usually declined over time in long term experiments. The use of the sedimentation device eliminated progressive deterioration of reactor performance usually associated with a perfusion device. |
---|---|