Robust, fully automatic delineation of the head contour by stereotactical normalization for attenuation correction according to Chang in dopamine transporter scintigraphy

Objectives Chang’s method, the most widely used attenuation correction (AC) in brain single-photon emission computed tomography (SPECT), requires delineation of the outer contour of the head. Manual and automatic threshold-based methods are prone to errors due to variability of tracer uptake in the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European radiology 2015-09, Vol.25 (9), p.2709-2717
Hauptverfasser: Lange, Catharina, Kurth, Jens, Seese, Anita, Schwarzenböck, Sarah, Steinhoff, Karen, Umland-Seidler, Bert, Krause, Bernd J., Brenner, Winfried, Sabri, Osama, Hesse, Swen, Buchert, Ralph
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives Chang’s method, the most widely used attenuation correction (AC) in brain single-photon emission computed tomography (SPECT), requires delineation of the outer contour of the head. Manual and automatic threshold-based methods are prone to errors due to variability of tracer uptake in the scalp. The present study proposes a new method for fully automated delineation of the head based on stereotactical normalization. The method was validated for SPECT with I-123-ioflupane. Methods The new method was compared to threshold-based delineation in 62 unselected patients who had received I-123-ioflupane SPECT at one of 3 centres. The impact on diagnostic power was tested for semi-quantitative analysis and visual reading of the SPECT images (six independent readers). Results The two delineation methods produced highly consistent semi-quantitative results. This was confirmed by receiver operating characteristic analyses in which the putamen specific-to-background ratio achieved highest area under the curve with negligible effect of the delineation method: 0.935 versus 0.938 for stereotactical normalization and threshold-based delineation, respectively. Visual interpretation of DVR images was also not affected by the delineation method. Conclusions Delineation of the head contour by stereotactical normalization appears useful for Chang AC in I-123-ioflupane SPECT. It is robust and does not require user interaction. Key Points •Chang attenuation correction in brain SPECT requires delineation of the head contour . •Manual and threshold-based methods are prone to errors . •The study proposes a fully-automated method for delineation based on stereotactical normalization . •The method is shown to work reliably in I-123-ioflupane SPECT . •It might improve the workflow of I-123-ioflupane SPECT in everyday patient care .
ISSN:0938-7994
1432-1084
DOI:10.1007/s00330-015-3667-6