Porous carbon-modified electrodes as highly selective and sensitive sensors for detection of dopamine

Carbon porous materials (CPMs) with high surface areas up to 2660 m(2) g(-1), directly fabricated by a facile microwave-assisted route, were applied to the electrochemical detection of dopamine (DA). The CPM-modified electrodes exhibited excellent selectivity, a desirable detection limit (2.9 nM), a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analyst (London) 2014-10, Vol.139 (19), p.4994-5000
Hauptverfasser: Veerakumar, Pitchaimani, Madhu, Rajesh, Chen, Shen-Ming, Hung, Chin-Te, Tang, Pi-Hsi, Wang, Chen-Bin, Liu, Shang-Bin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Carbon porous materials (CPMs) with high surface areas up to 2660 m(2) g(-1), directly fabricated by a facile microwave-assisted route, were applied to the electrochemical detection of dopamine (DA). The CPM-modified electrodes exhibited excellent selectivity, a desirable detection limit (2.9 nM), and extraordinary sensitivity (2.56 mA μM(-1) cm(-2)) for detection of DA, even in the presence of large amounts of foreign species, such as ascorbic acid (AA) and uric acid (UA), making feasible the practical applications of these electrodes as DA sensors.
ISSN:0003-2654
1364-5528
DOI:10.1039/c4an01083c