Soaps and Detergents: Alternatives to Animal Eye Irritation Tests
An extensive computer search was conducted, and a comprehensive overview of the current status of alternatives to animal eye irritation tests was obtained. A search of Medline and Toxline databases (1988 to present) was supplemented with references from sources regarding in vitro eye irritation. Par...
Gespeichert in:
Veröffentlicht in: | Journal of the American College of Toxicology 1996-02, Vol.15 (1), p.1-44 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An extensive computer search was conducted, and a comprehensive overview of the current status of alternatives to animal eye irritation tests was obtained. A search of Medline and Toxline databases (1988 to present) was supplemented with references from sources regarding in vitro eye irritation. Particular attention was paid to soap and detergent products and related ingredients. Eighty-five references are included in the review; the in vitro assays are categorized, and their predictive values for assessing acute ocular irritation are evaluated and compared with the Draize rabbit eye irritation assay and with each other. The present review shows that the increased activity of scientists from academia, industry, and regulatory agencies has resulted in substantial progress in developing alternative in vitro procedures and that a number of large, interlaboratory evaluations and international workshops have assisted in the selection process. However, none of these methodologies has obtained acceptance for regulatory classification purposes. Conclusions drawn from this review include that (a) no single in vitro assay is considered capable of replacing the Draize eye irritation test; (b) the chorioallantoic membrane vascular assay (CAMVA) or the hen egg test-chorio-allantoic membrane test (HET-CAM), the chicken or bovine enucleated eye test, the neutral red and plasminogen activation assays for cytotoxicity, and the silicon microphysiometer appear to have the greatest potential as screening tools for eye irritation; and (c) choosing a specific assay or series of assays will depend on the type of agent tested and the impact of false-negative or false-positive results. New assays will continue to be developed and should be included in future evaluations, when sufficient data are available. |
---|---|
ISSN: | 0730-0913 |
DOI: | 10.3109/10915819609008705 |