Rate of lower-extremity ultrasonography in trauma patients is associated with rate of deep venous thrombosis but not pulmonary embolism

Background Disparate lower-extremity ultrasonography (LUS) screening practices among trauma institutions reflecta lack of consensus regarding screening indications and whether screening improves outcomes. We hypothesized that LUS screening for deep-vein thrombosis (DVT) is not associated with a redu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgery 2015-08, Vol.158 (2), p.379-385
Hauptverfasser: Dietch, Zachary C., MD, MBA, Edwards, Brandy L., MD, MSc, Thames, Matthew, BA, Shah, Puja M., MD, Williams, Michael D., MD, FACS, Sawyer, Robert G., MD, FACS
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Disparate lower-extremity ultrasonography (LUS) screening practices among trauma institutions reflecta lack of consensus regarding screening indications and whether screening improves outcomes. We hypothesized that LUS screening for deep-vein thrombosis (DVT) is not associated with a reduced incidence of pulmonary embolism (PE). Methods The 2012 ACS National Trauma Data Bank Research Data Set was queried to identify 442,108 patients treated at institutions reporting at least one LUS and at least one DVT. Institutions performing LUS on more than 2% of admitted patients were designated high-screening facilities and remaining institutions were designated low-screening facilities. Patient characteristics and risk factors were used to develop a logistic regression model to assess the independent associations between LUS and DVT and between LUS and PE. Results Overall, DVT and PE were reported in 0.94% and 0.37% of the study population, respectively. DVT and PE were reported more commonly in designated high-screening than low-screening facilities (DVT: 1.12% vs 0.72%, P  
ISSN:0039-6060
1532-7361
DOI:10.1016/j.surg.2015.03.052