Improving the Utility of Laryngeal Adductor Reflex Testing: A Translational Tale of Mice and Men
Objectives Evaluation of the laryngeal adductor reflex (LAR) entails delivering air through an endoscope positioned 1 to 2 mm from the arytenoid mucosa to elicit bilateral vocal fold (VF) closure. This short working distance limits visualization to only the ipsilateral arytenoid and results in quant...
Gespeichert in:
Veröffentlicht in: | Otolaryngology-head and neck surgery 2015-07, Vol.153 (1), p.94-101 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives
Evaluation of the laryngeal adductor reflex (LAR) entails delivering air through an endoscope positioned 1 to 2 mm from the arytenoid mucosa to elicit bilateral vocal fold (VF) closure. This short working distance limits visualization to only the ipsilateral arytenoid and results in quantification of a single LAR metric: threshold pressure that evokes the LAR. Our goal was to evolve the LAR procedure to optimize its utility in clinical practice and translational research.
Study Design
Prospective translational experiment.
Setting
Academic institution.
Subjects
Young healthy human adults (n = 13) and 3 groups of mice: healthy, primary aging mice (n = 5), a transgenic mouse model of amyotrophic lateral sclerosis (ALS; n = 4), and young healthy controls (n = 10).
Methods
The VFs were visualized bilaterally during supramaximal air stimulation through an endoscope. Responses were analyzed to quantify 4 novel metrics: VF adduction phase duration, complete glottic closure duration, VF abduction phase duration, and total LAR duration.
Results
The 4 LAR metrics are remarkably similar between healthy young humans and mice. Compared to control mice, aging mice have shorter glottic closure durations, whereas ALS-affected mice have shorter VF abduction phase durations.
Conclusions
We have established a new LAR protocol that permits quantification of novel LAR metrics that are translatable between mice and humans. Using this protocol, we showed that VF adduction is impaired in primary aging mice, whereas VF abduction is impaired in ALS-affected mice. These preliminary findings highlight the enhanced diagnostic potential of LAR testing. |
---|---|