Mechanical behavior of the U-anchor of super-CFRP rod under tensile loading
A suitable anchoring system is required to anchor a CFRP tendon due to its sensitivity in lateral pressure. Recent developed anchors are still relying on lateral pressure in anchoring CFRP tendons. A new CFRP unit equipped with U-anchor at both end of the rod body without any jointing (namely of Sup...
Gespeichert in:
Veröffentlicht in: | Journal of composite materials 2014-06, Vol.48 (15), p.1875-1885 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A suitable anchoring system is required to anchor a CFRP tendon due to its sensitivity in lateral pressure. Recent developed anchors are still relying on lateral pressure in anchoring CFRP tendons. A new CFRP unit equipped with U-anchor at both end of the rod body without any jointing (namely of Super CFRP, S-CFRP) has been developed. This paper presents the mechanical behavior as well as failure mechanism of U-anchor under direct loading and loaded under embedded within concrete, respectively. The rupture occurred on the circular part of U-anchor under direct loading. The stress concentration on circular loop was the cause of U-anchor rupture. Loading of U-anchor embedded within concrete indicated an optimum capacity. The failure was out of the anchor system. Finite element model of U-anchor embedded within concrete showed better stress distribution on anchor at rupture load such that the stress on U-anchor was lower than CFRP strength. |
---|---|
ISSN: | 0021-9983 1530-793X |
DOI: | 10.1177/0021998313491514 |