Applying ATP bioluminescence to design and evaluate a successful new intensive care unit cleaning programme

Summary This was a two-phase prospective intervention study in the cardiology intensive care unit (CICU) and medical intensive care unit (MICU) and of a public 1800-bed medical centre in Taiwan. In phase I, cleaning efficacy was monitored by ATP bioluminescence after daily morning cleaning, and only...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of hospital infection 2015-08, Vol.90 (4), p.344-346
Hauptverfasser: Chan, M.-C, Lin, T.-Y, Chiu, Y.-H, Huang, T.-F, Chiu, S.-K, Liu, T.-L, Hung, P.-S, Chang, C.-M, Lin, J.-C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Summary This was a two-phase prospective intervention study in the cardiology intensive care unit (CICU) and medical intensive care unit (MICU) and of a public 1800-bed medical centre in Taiwan. In phase I, cleaning efficacy was monitored by ATP bioluminescence after daily morning cleaning, and only 43.9% of 221 tested surfaces passed. The baseline data were used to define an intervention consisting of a new cleaning protocol as well as a new education/training programme. In phase II, following the intervention, 88.1% of 270 surfaces were found to be clean. The combined infection rate in the CICU and MICU showed a statistically significant decrease of 49.7%.
ISSN:0195-6701
1532-2939
DOI:10.1016/j.jhin.2015.04.008