Applying ATP bioluminescence to design and evaluate a successful new intensive care unit cleaning programme
Summary This was a two-phase prospective intervention study in the cardiology intensive care unit (CICU) and medical intensive care unit (MICU) and of a public 1800-bed medical centre in Taiwan. In phase I, cleaning efficacy was monitored by ATP bioluminescence after daily morning cleaning, and only...
Gespeichert in:
Veröffentlicht in: | The Journal of hospital infection 2015-08, Vol.90 (4), p.344-346 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Summary This was a two-phase prospective intervention study in the cardiology intensive care unit (CICU) and medical intensive care unit (MICU) and of a public 1800-bed medical centre in Taiwan. In phase I, cleaning efficacy was monitored by ATP bioluminescence after daily morning cleaning, and only 43.9% of 221 tested surfaces passed. The baseline data were used to define an intervention consisting of a new cleaning protocol as well as a new education/training programme. In phase II, following the intervention, 88.1% of 270 surfaces were found to be clean. The combined infection rate in the CICU and MICU showed a statistically significant decrease of 49.7%. |
---|---|
ISSN: | 0195-6701 1532-2939 |
DOI: | 10.1016/j.jhin.2015.04.008 |