Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1

[Display omitted] •First amperometric magnetoimmunosensor for Ara h 1 determination.•Sensitive and selective detection of Ara h 1 in 2h.•LOD of 6.3ngmL−1.•Determinations in food extracts and saliva.•Potential applicability in food safety and consumer protection. A highly sensitive disposable amperom...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2015-06, Vol.880, p.52-59
Hauptverfasser: Montiel, V. Ruiz-Valdepeñas, Campuzano, S., Pellicanò, A., Torrente-Rodríguez, R.M., Reviejo, A.J., Cosio, M.S., Pingarrón, J.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 59
container_issue
container_start_page 52
container_title Analytica chimica acta
container_volume 880
creator Montiel, V. Ruiz-Valdepeñas
Campuzano, S.
Pellicanò, A.
Torrente-Rodríguez, R.M.
Reviejo, A.J.
Cosio, M.S.
Pingarrón, J.M.
description [Display omitted] •First amperometric magnetoimmunosensor for Ara h 1 determination.•Sensitive and selective detection of Ara h 1 in 2h.•LOD of 6.3ngmL−1.•Determinations in food extracts and saliva.•Potential applicability in food safety and consumer protection. A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at −0.20V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H2O2 as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0ngmL−1 Ara h 1, a detection limit of 6.3ngmL−1, a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1.
doi_str_mv 10.1016/j.aca.2015.04.041
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1690210033</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267015005516</els_id><sourcerecordid>1690210033</sourcerecordid><originalsourceid>FETCH-LOGICAL-c423t-9c2176c144cf577487bc18719e4bf839bbd91e70b91dfa20686b40ea596887523</originalsourceid><addsrcrecordid>eNp9kMFqGzEQhkVJqR23D9BL0TGXdTWSvNolJxOSpmDIoe1ZaKVZW2ZXcqS1IW9fuU5zDAwSw3zzw3yEfAW2BAb19_3SWLPkDFZLJkvBBzKHRolKCi6vyJwxJipeKzYj1znvS8uByU9kxmvWciHUnLhfGLKf_AmpCY5mHND-60azDThFP47HEPMZClt6GMzUxzTS8lCHE6bRBzP5GGjs6bTDMoiOmmHAtMVA18nQHYXP5GNvhoxfXv8F-fNw__vusdo8_fh5t95UVnIxVa3loGoLUtp-pZRsVGfLOdCi7PpGtF3nWkDFuhZcbzirm7qTDM2qrZtGrbhYkJtL7iHF5yPmSY8-WxwGEzAes4a6PRtgQhQULqhNMeeEvT4kP5r0ooHps1y910WuPsvVTJaCsvPtNf7YjejeNv7bLMDtBcBy5Mlj0tl6DBadT0WrdtG_E_8Xm5CJ-A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1690210033</pqid></control><display><type>article</type><title>Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Montiel, V. Ruiz-Valdepeñas ; Campuzano, S. ; Pellicanò, A. ; Torrente-Rodríguez, R.M. ; Reviejo, A.J. ; Cosio, M.S. ; Pingarrón, J.M.</creator><creatorcontrib>Montiel, V. Ruiz-Valdepeñas ; Campuzano, S. ; Pellicanò, A. ; Torrente-Rodríguez, R.M. ; Reviejo, A.J. ; Cosio, M.S. ; Pingarrón, J.M.</creatorcontrib><description>[Display omitted] •First amperometric magnetoimmunosensor for Ara h 1 determination.•Sensitive and selective detection of Ara h 1 in 2h.•LOD of 6.3ngmL−1.•Determinations in food extracts and saliva.•Potential applicability in food safety and consumer protection. A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at −0.20V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H2O2 as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0ngmL−1 Ara h 1, a detection limit of 6.3ngmL−1, a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2015.04.041</identifier><identifier>PMID: 26092337</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Amperometric immunosensor ; Antibodies, Monoclonal - chemistry ; Antibodies, Monoclonal - immunology ; Antigens, Plant - analysis ; Antigens, Plant - immunology ; Ara h 1 ; Biosensing Techniques ; Biotin - chemistry ; Biotinylation ; Electrochemical Techniques ; Electrodes ; Electron Transport ; Food extracts ; Glycoproteins - analysis ; Glycoproteins - immunology ; Hydrogen Peroxide - chemistry ; Hydroquinones - chemistry ; Immunoconjugates - chemistry ; Immunoconjugates - immunology ; Limit of Detection ; Magnetic beads ; Magnetics ; Plant Proteins - analysis ; Plant Proteins - immunology ; Saliva ; Screen-printed electrode</subject><ispartof>Analytica chimica acta, 2015-06, Vol.880, p.52-59</ispartof><rights>2015 Elsevier B.V.</rights><rights>Copyright © 2015 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c423t-9c2176c144cf577487bc18719e4bf839bbd91e70b91dfa20686b40ea596887523</citedby><cites>FETCH-LOGICAL-c423t-9c2176c144cf577487bc18719e4bf839bbd91e70b91dfa20686b40ea596887523</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.aca.2015.04.041$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26092337$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Montiel, V. Ruiz-Valdepeñas</creatorcontrib><creatorcontrib>Campuzano, S.</creatorcontrib><creatorcontrib>Pellicanò, A.</creatorcontrib><creatorcontrib>Torrente-Rodríguez, R.M.</creatorcontrib><creatorcontrib>Reviejo, A.J.</creatorcontrib><creatorcontrib>Cosio, M.S.</creatorcontrib><creatorcontrib>Pingarrón, J.M.</creatorcontrib><title>Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>[Display omitted] •First amperometric magnetoimmunosensor for Ara h 1 determination.•Sensitive and selective detection of Ara h 1 in 2h.•LOD of 6.3ngmL−1.•Determinations in food extracts and saliva.•Potential applicability in food safety and consumer protection. A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at −0.20V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H2O2 as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0ngmL−1 Ara h 1, a detection limit of 6.3ngmL−1, a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1.</description><subject>Amperometric immunosensor</subject><subject>Antibodies, Monoclonal - chemistry</subject><subject>Antibodies, Monoclonal - immunology</subject><subject>Antigens, Plant - analysis</subject><subject>Antigens, Plant - immunology</subject><subject>Ara h 1</subject><subject>Biosensing Techniques</subject><subject>Biotin - chemistry</subject><subject>Biotinylation</subject><subject>Electrochemical Techniques</subject><subject>Electrodes</subject><subject>Electron Transport</subject><subject>Food extracts</subject><subject>Glycoproteins - analysis</subject><subject>Glycoproteins - immunology</subject><subject>Hydrogen Peroxide - chemistry</subject><subject>Hydroquinones - chemistry</subject><subject>Immunoconjugates - chemistry</subject><subject>Immunoconjugates - immunology</subject><subject>Limit of Detection</subject><subject>Magnetic beads</subject><subject>Magnetics</subject><subject>Plant Proteins - analysis</subject><subject>Plant Proteins - immunology</subject><subject>Saliva</subject><subject>Screen-printed electrode</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kMFqGzEQhkVJqR23D9BL0TGXdTWSvNolJxOSpmDIoe1ZaKVZW2ZXcqS1IW9fuU5zDAwSw3zzw3yEfAW2BAb19_3SWLPkDFZLJkvBBzKHRolKCi6vyJwxJipeKzYj1znvS8uByU9kxmvWciHUnLhfGLKf_AmpCY5mHND-60azDThFP47HEPMZClt6GMzUxzTS8lCHE6bRBzP5GGjs6bTDMoiOmmHAtMVA18nQHYXP5GNvhoxfXv8F-fNw__vusdo8_fh5t95UVnIxVa3loGoLUtp-pZRsVGfLOdCi7PpGtF3nWkDFuhZcbzirm7qTDM2qrZtGrbhYkJtL7iHF5yPmSY8-WxwGEzAes4a6PRtgQhQULqhNMeeEvT4kP5r0ooHps1y910WuPsvVTJaCsvPtNf7YjejeNv7bLMDtBcBy5Mlj0tl6DBadT0WrdtG_E_8Xm5CJ-A</recordid><startdate>20150623</startdate><enddate>20150623</enddate><creator>Montiel, V. Ruiz-Valdepeñas</creator><creator>Campuzano, S.</creator><creator>Pellicanò, A.</creator><creator>Torrente-Rodríguez, R.M.</creator><creator>Reviejo, A.J.</creator><creator>Cosio, M.S.</creator><creator>Pingarrón, J.M.</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20150623</creationdate><title>Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1</title><author>Montiel, V. Ruiz-Valdepeñas ; Campuzano, S. ; Pellicanò, A. ; Torrente-Rodríguez, R.M. ; Reviejo, A.J. ; Cosio, M.S. ; Pingarrón, J.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c423t-9c2176c144cf577487bc18719e4bf839bbd91e70b91dfa20686b40ea596887523</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Amperometric immunosensor</topic><topic>Antibodies, Monoclonal - chemistry</topic><topic>Antibodies, Monoclonal - immunology</topic><topic>Antigens, Plant - analysis</topic><topic>Antigens, Plant - immunology</topic><topic>Ara h 1</topic><topic>Biosensing Techniques</topic><topic>Biotin - chemistry</topic><topic>Biotinylation</topic><topic>Electrochemical Techniques</topic><topic>Electrodes</topic><topic>Electron Transport</topic><topic>Food extracts</topic><topic>Glycoproteins - analysis</topic><topic>Glycoproteins - immunology</topic><topic>Hydrogen Peroxide - chemistry</topic><topic>Hydroquinones - chemistry</topic><topic>Immunoconjugates - chemistry</topic><topic>Immunoconjugates - immunology</topic><topic>Limit of Detection</topic><topic>Magnetic beads</topic><topic>Magnetics</topic><topic>Plant Proteins - analysis</topic><topic>Plant Proteins - immunology</topic><topic>Saliva</topic><topic>Screen-printed electrode</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Montiel, V. Ruiz-Valdepeñas</creatorcontrib><creatorcontrib>Campuzano, S.</creatorcontrib><creatorcontrib>Pellicanò, A.</creatorcontrib><creatorcontrib>Torrente-Rodríguez, R.M.</creatorcontrib><creatorcontrib>Reviejo, A.J.</creatorcontrib><creatorcontrib>Cosio, M.S.</creatorcontrib><creatorcontrib>Pingarrón, J.M.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Montiel, V. Ruiz-Valdepeñas</au><au>Campuzano, S.</au><au>Pellicanò, A.</au><au>Torrente-Rodríguez, R.M.</au><au>Reviejo, A.J.</au><au>Cosio, M.S.</au><au>Pingarrón, J.M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2015-06-23</date><risdate>2015</risdate><volume>880</volume><spage>52</spage><epage>59</epage><pages>52-59</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><abstract>[Display omitted] •First amperometric magnetoimmunosensor for Ara h 1 determination.•Sensitive and selective detection of Ara h 1 in 2h.•LOD of 6.3ngmL−1.•Determinations in food extracts and saliva.•Potential applicability in food safety and consumer protection. A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at −0.20V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H2O2 as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0ngmL−1 Ara h 1, a detection limit of 6.3ngmL−1, a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>26092337</pmid><doi>10.1016/j.aca.2015.04.041</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2015-06, Vol.880, p.52-59
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_1690210033
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Amperometric immunosensor
Antibodies, Monoclonal - chemistry
Antibodies, Monoclonal - immunology
Antigens, Plant - analysis
Antigens, Plant - immunology
Ara h 1
Biosensing Techniques
Biotin - chemistry
Biotinylation
Electrochemical Techniques
Electrodes
Electron Transport
Food extracts
Glycoproteins - analysis
Glycoproteins - immunology
Hydrogen Peroxide - chemistry
Hydroquinones - chemistry
Immunoconjugates - chemistry
Immunoconjugates - immunology
Limit of Detection
Magnetic beads
Magnetics
Plant Proteins - analysis
Plant Proteins - immunology
Saliva
Screen-printed electrode
title Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T11%3A13%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitive%20and%20selective%20magnetoimmunosensing%20platform%20for%20determination%20of%20the%20food%20allergen%20Ara%20h%201&rft.jtitle=Analytica%20chimica%20acta&rft.au=Montiel,%20V.%20Ruiz-Valdepe%C3%B1as&rft.date=2015-06-23&rft.volume=880&rft.spage=52&rft.epage=59&rft.pages=52-59&rft.issn=0003-2670&rft.eissn=1873-4324&rft_id=info:doi/10.1016/j.aca.2015.04.041&rft_dat=%3Cproquest_cross%3E1690210033%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1690210033&rft_id=info:pmid/26092337&rft_els_id=S0003267015005516&rfr_iscdi=true