In vivo support for the new concept of pulmonary blood flow-mediated CO2 gas excretion in the lungs

To further examine the validity of the proposed concept of pulmonary blood flow-dependent CO2 gas excretion in the lungs, we investigated the effects of intramediastinal balloon catheterization-, pulmonary artery catheterization-, or isoprenaline (ISP)-induced changes in pulmonary blood flow on the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of physiology. Lung cellular and molecular physiology 2015-06, Vol.308 (12), p.L1224-L1236
Hauptverfasser: Kawai, Yoshiko, Ajima, Kumiko, Kaidoh, Maki, Sakaguchi, Masao, Tanaka, Satoshi, Kawamata, Mikito, Kimura, Hiroko, Ohhashi, Toshio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To further examine the validity of the proposed concept of pulmonary blood flow-dependent CO2 gas excretion in the lungs, we investigated the effects of intramediastinal balloon catheterization-, pulmonary artery catheterization-, or isoprenaline (ISP)-induced changes in pulmonary blood flow on the end-expiratory CO2 gas pressure (PeCO2 ), the maximal velocity of the pulmonary artery (Max Vp), systemic arterial pressure, and heart rate of anesthetized rabbits. We also evaluated the changes in the PeCO2 in clinical models of anemia or pulmonary embolism. An almost linear relationship was detected between the PeCO2 and Max Vp. In an experiment in which small pulmonary arteries were subjected to stenosis, the PeCO2 fell rapidly, and the speed of the reduction was dependent on the degree of stenosis. ISP produced significant increases in the PeCO2 of the anesthetized rabbits. Conversely, treatment with piceatannol or acetazolamide induced significant reductions in the PeCO2 . Treatment with a cell surface F1/FO ATP synthase antibody caused significant reductions in the PeCO2 itself and the ISP-induced increase in the PeCO2 . Neither the PeCO2 nor SAP was significantly influenced by marked anemia [%hematocrit (Ht), 70 ∼ 47%]. On the other hand, in the presence of less severe anemia (%Ht: 100 ∼ 70%) both the PeCO2 and SAP fell significantly when the rabbits' blood viscosity was decreased. The rabbits in which pulmonary embolisms were induced demonstrated significantly reduced PeCO2 values, which was compatible with the lowering of their Max Vp. In conclusion, we reaffirm the validity of the proposed concept of CO2 gas exchange in the lungs.
ISSN:1522-1504
DOI:10.1152/ajplung.00205.2014