Impact of Hamstring Graft Diameter on Tendon Strength: A Biomechanical Study

Purpose The purpose of this study was to compare the tensile strength of hamstring grafts of varying combined pull-through diameters within the clinically relevant range of 6 to 9 mm. Methods We tested 44 non-irradiated allograft hamstring grafts (11 per group). Combined looped semitendinosus and gr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arthroscopy 2015-06, Vol.31 (6), p.1084-1090
Hauptverfasser: Boniello, Michael R., M.S, Schwingler, Paul M., M.D, Bonner, Justin M, Robinson, Samuel P., M.D, Cotter, Andrew, B.S, Bonner, Kevin F., M.D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose The purpose of this study was to compare the tensile strength of hamstring grafts of varying combined pull-through diameters within the clinically relevant range of 6 to 9 mm. Methods We tested 44 non-irradiated allograft hamstring grafts (11 per group). Combined looped semitendinosus and gracilis grafts were allocated to the 6-, 7-, 8-, or 9-mm group based on the smallest-diameter lumen that the graft could be “pulled through” using a surgical sizing instrument. Testing was performed on an Instron materials testing machine (Instron, Norwood, MA). Samples were secured with cryoclamps, prestressed, and pulled to failure at a rate of 10% gauge length per second. Results The mean load to failure was 2,359 ± 474 N, 3,263 ± 677 N, 3,908 ± 556 N, and 4,360 ± 606 N for the 6-, 7-, 8-, and 9-mm grafts, respectively. Minimum failure loads were as low as 1,567 N, 2,288 N, 2,874 N, and 3,720 N for each group, respectively. There were statistically significant differences between the 6- and 7-mm, 6- and 8-mm, 6- and 9-mm, and 7- and 9-mm groups ( P  = .01). Conclusions Statistically different increasing tensile strength was seen as graft diameter increased. Significant variability exists in the strength of multi-stranded hamstring allografts within the diameter range of 6 to 9 mm that often falls well below the commonly accepted value of 4,000 N for a hamstring graft. Clinical Relevance Recent evidence suggests a higher early failure rate of hamstring autografts in subsets of patients with graft diameters of 8 mm or less. This study may increase awareness that hamstring grafts may not be nearly as strong as previously appreciated and that increasing tendon diameters by 1 to 2 mm may dramatically affect graft strength. These data may be helpful in preoperative discussions regarding variable hamstring size, strength, and potential intraoperative augmentation options.
ISSN:0749-8063
1526-3231
DOI:10.1016/j.arthro.2014.12.023