A novel approach for copy number variation analysis by combining multiplex PCR with matrix-assisted laser desorption ionization time-of-flight mass spectrometry

•We developed an approach for copy number detection.•This approach produced consistent and accurate results.•This approach has high throughput.•This approach can precisely detect copy numbers over a wide range. With the increasing interest in copy number variation as it pertains to human genomic var...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biotechnology 2013-06, Vol.166 (1-2), p.6-11
Hauptverfasser: Gao, Yonghui, Chen, Xiaoli, Wang, Jianhua, Shangguan, Shaofang, Dai, Yaohua, Zhang, Ting, Liu, Junling
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•We developed an approach for copy number detection.•This approach produced consistent and accurate results.•This approach has high throughput.•This approach can precisely detect copy numbers over a wide range. With the increasing interest in copy number variation as it pertains to human genomic variation, common phenotypes, and disease susceptibility, there is a pressing need for methods to accurately identify copy number. In this study, we developed a simple approach that combines multiplex PCR with matrix-assisted laser desorption ionization time-of-flight mass spectrometry for submicroscopic copy number variation detection. Two pairs of primers were used to simultaneously amplify query and endogenous control regions in the same reaction. Using a base extension reaction, the two amplicons were then distinguished and quantified in a mass spectrometry map. The peak ratio between the test region and the endogenous control region was manually calculated. The relative copy number could be determined by comparing the peak ratio between the test and control samples. This method generated a copy number measurement comparable to those produced by two other commonly used methods – multiplex ligation-dependent probe amplification and quantitative real-time PCR. Furthermore, it can discriminate a wide range of copy numbers. With a typical 384-format SpectroCHIP, at least six loci on 384 samples can be analyzed simultaneously in a hexaplex assay, making this assay adaptable for high throughput, and potentially applicable for large-scale association studies.
ISSN:0168-1656
1873-4863
DOI:10.1016/j.jbiotec.2013.04.006